Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-161
D.. Reference Value
Par. Description Fieldbus-
address
D113
Axis, OFF
r=1, w=1
Additional enable 2 source: The signal additional enable 2 is logically linked with the
reference value enables. When these are activated (see D55), additional enable 2, a reference
value enable and the device enable must assume the value 1:active before the drive can be
enabled.
The parameter D113 specifies the source for the signal. The selections 0:low and 1:high
correspond to fixed signal levels. When the selection is 2:parameter, the control word D210 Bit13 is
used as the source. The control word can be written via fieldbus.
Regardless of the selected source, the signal is indicated in D313. When the signal is to be
processed with time delay, a "switch on" delay can be parameterized in D413.0 and a "switch off"
delay in D413.1.
0: Low;
1: High;
2: parameter;
3: BE1;
4: BE1-inverted;
5: BE2;
6: BE2-inverted;
7: BE3;
8: BE3-inverted;
9: BE4;
10: BE4-inverted;
11: BE5;
12: BE5-inverted;
13: BE6;
14: BE6-inverted;
15: BE7;
16: BE7-inverted;
17: BE8;
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1C 40 00 hex
2671h 0h
D114
Axis, OFF
r=1, w=1
Motorised pot up source: A HIGH level of the signal motorized pot UP increases the
motorized pot reference value as step or continuously, depending on D43.
The parameter D114 specifies the source for the signal motorized pot UP. The selections 0:low and
1:high correspond to fixed signal levels. When the selection is 2:parameter, the control word D211
Bit0 is used as the source. The control word can be written via fieldbus.
Regardless of the selected source, the signal is indicated in D314.
0: Low;
1: High;
2: parameter;
3: BE1;
4: BE1-inverted;
5: BE2;
6: BE2-inverted;
7: BE3;
8: BE3-inverted;
9: BE4;
10: BE4-inverted;
11: BE5;
12: BE5-inverted;
13: BE6;
14: BE6-inverted;
2672h 0h