Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-160
D.. Reference Value
Par. Description Fieldbus-
address
10: BE4-inverted;
11: BE5;
12: BE5-inverted;
13: BE6;
14: BE6-inverted;
15: BE7;
16: BE7-inverted;
17: BE8;
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1B C0 00 hex
D112
Axis, OFF
r=1, w=1
Speed / torque switch source: The signal speed / torque switch can be used to switch
between speed and torque control when the drive is enabled. Speed control is active with a low
level. Torque control is used for a high level.
The parameter D112 specifies the source of the signal speed / torque switch. The selections 0:low
and 1:high correspond to fixed signal levels. Control word D210 Bit12 is used as the source for
selection 2:parameter. The control word can be written via fieldbus.
Regardless of the selected source, the signal is indicated in D312. If the signal is to be processed
with a time delay, a "switch on" delay can be parameterized in D412.0 and a "switch off" delay in
D412.1.
0: Low;
1: High;
2: parameter;
3: BE1;
4: BE1-inverted;
5: BE2;
6: BE2-inverted;
7: BE3;
8: BE3-inverted;
9: BE4;
10: BE4-inverted;
11: BE5;
12: BE5-inverted;
13: BE6;
14: BE6-inverted;
15: BE7;
16: BE7-inverted;
17: BE8;
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1C 00 00 hex
2670h 0h