Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-158
D.. Reference Value
Par. Description Fieldbus-
address
8: BE3-inverted;
9: BE4;
10: BE4-inverted;
11: BE5;
12: BE5-inverted;
13: BE6;
14: BE6-inverted;
15: BE7;
16: BE7-inverted;
17: BE8;
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1B 00 00 hex
D109
Axis, OFF
r=1, w=1
Negative blocking source: When the signal negative direction blocking assumes the value
1:active, no negative reference value is processed. When the direction is blocked during operation,
the drive decelerates to a standstill with the respectively valid decelerating ramp.
The parameter D109 specifies the source for the signal. The selections 0:low and 1:high
correspond to fixed signal levels. When the selection is 2:parameter, the control word D210 Bit9 is
used as the source. The control word can be written via fieldbus.
Regardless of the selected source, the signal is indicated in D309. When the signal is to be
processed with time delay, a "switch on" delay can be parameterized in D409.0 and a "switch off"
delay in D409.1.
0: Low;
1: High;
2: parameter;
3: BE1;
4: BE1-inverted;
5: BE2;
6: BE2-inverted;
7: BE3;
8: BE3-inverted;
9: BE4;
10: BE4-inverted;
11: BE5;
12: BE5-inverted;
13: BE6;
14: BE6-inverted;
15: BE7;
16: BE7-inverted;
17: BE8;
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1B 40 00 hex
266Dh 0h