Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-155
D.. Reference Value
Par. Description Fieldbus-
address
12: BE5-inverted;
13: BE6;
14: BE6-inverted;
15: BE7;
16: BE7-inverted;
17: BE8;
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 19 C0 00 hex
D104
Axis, OFF
r=1, w=1
Limit switch- source: When the end switch- signal is active, application event 5 is triggered.
The type of reaction and the text to be displayed can be specified in parameters U150 to U152. The
standard reaction is that the device assumes the "fault" state. The direction after the limit switch is
passed over is blocked. After the fault is acknowledged, the drive can continue in the direction
opposite from the switch.
The parameter D104 specifies the source of the signal. The selections 0:low and 1:high correspond
to fixed signal levels. Control word D210 Bit4 is used as the source for selection 2:parameter. The
control word can be written via fieldbus.
Regardless of the selected source, the signal is indicated in D304. If the signal is to be processed
with a time delay, a "switch on" delay can be parameterized in D404.0 and a "switch off" delay in
D404.1.
0: Low;
1: High;
2: parameter;
3: BE1;
4: BE1-inverted;
5: BE2;
6: BE2-inverted;
7: BE3;
8: BE3-inverted;
9: BE4;
10: BE4-inverted;
11: BE5;
12: BE5-inverted;
13: BE6;
14: BE6-inverted;
15: BE7;
16: BE7-inverted;
17: BE8;
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1A 00 00 hex
2668h 0h