Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-152
D.. Reference Value
Par. Description Fieldbus-
address
D98.0
Axis
r=3, w=3
I32 scaled source: Parameters D98.X and D99.X can be used to convert I32 values related to
D56 into I16 values. The I32 parameters are entered in D98.X. The value converted to I16 can be
read in array D99.X in the same element.
The scaling function makes it possible to use I32 values in range control and for output to analog
outputs.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 04 18 80 00 hex
2662h
Array
0h
D98.1
Axis
r=3, w=3
I32 scaled source
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 04 18 80 01 hex
2662h
Array
1h
D98.2
Axis
r=3, w=3
I32 scaled source
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 04 18 80 02 hex
2662h
Array
2h
D98.3
Axis
r=3, w=3
I32 scaled source
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 04 18 80 03 hex
2662h
Array
3h
D99.0
Axis
read (3)
I16 scaled value: Parameters D98.X and D99.X can be used to convert I32 values related to
D56 into I16 values. The I32 parameters are entered in D98.X. The value converted to I16 can be
read in array D99.X in the same element.
The scaling function makes it possible to use I32 values in range control and for output to analog
outputs.
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 04 18 C0 00 hex
2663h
Array
0h
D99.1
Axis
read (3)
I16 scaled value
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 04 18 C0 01 hex
2663h
Array
1h
D99.2
Axis
read (3)
I16 scaled value
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 04 18 C0 02 hex
2663h
Array
2h
D99.3
Axis
read (3)
I16 scaled value
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 04 18 C0 03 hex
2663h
Array
3h
D100
Axis, OFF
r=1, w=1
Reverse source: The Reverse (direction of revolution) signal reverses the direction of revolution
of the motor.
The parameter D100 specifies the source for the Reverse signal.
Possible selections 0:Low and 1:High are the same as fixed values. With D100=3:BE1...28:BE13-
inverse , the Reverse signal can be executed via the selected binary input. With D100=2:Para-
meter, the control byte or the control word of the selected application is used as the signal source.
This setting is provided for fieldbus operation. The control word can be assigned to various
parameters in the different applications. The list below shows the control words for the different
applications.
The Reverse signal can be monitored in D300 - regardless of the parameterized signal source.
Application Parameter Bit
Fast reference value D210 0
Technology controller G210 0
Comfort reference valuew D210 0
0: Low;
1: High;
2: parameter;
3: BE1;
4: BE1-inverted;
5: BE2;
2664h 0h