11. Used Parameters
KSW-148
D.. Reference Value
Par. Description Fieldbus-
address
D72
Axis
r=3, w=3
Range control 2 low pass filter: Range control 2 is defined by parameters D70 to D79. The
result is indicated in D195 to D199.
The value of the parameter entered in D70 is weighted with the factor D71. Low pass filtering takes
place afterwards. D72 specifies the filter time constants of the low pass.
Value range in ms: 0.0 ... 1,2 ... 200.1
Fieldbus: 1LSB=0,1ms; Type: I32; raw value:1LSB=Fnct.no.11; USS-Adr: 04 12 00 00 hex
2648h 0h
D73
Axis
r=3, w=3
Range control 2 mode: Range control 2 is defined by parameters D70 to D79. The result is
indicated in D195 to D199.
D73 determines how the value entered in D79 will be controlled. When D73 is set to 0:range, the
limits are evaluated unchanged. When D74 = 50% and D77 = 60% are parameterized, the valid
working range in this case is between 50% and 60%. A value of -55% is invalid and triggers event
62.
With1:absolute the limits specified in D74 to D77 are evaluated symmetrically to zero. When D74 =
50% and D77 = 60% are parameterized, the valid working range is between +50% to +60% or -60%
and -50%. A value of the controlled parameter outside these ranges will cause the result 62 or 63.
0: range;
1: absolute;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 12 40 00 hex
2649h 0h
D74
Axis
r=3, w=3
Range control 2 lower limit 2: Range control 2 is defined by parameters D70 to D79. The
result is indicated in D195 to D199.
D74 determines the lower limit of range control. If D79 drops below this limit, the display occurs in
D195 and event 62 is triggered. The level of the event can be set in U120 to U122.
Value range in %: -800.0 ... -100,0 ... 800.0
Fieldbus: 1LSB=0,1%; Type: I16; (raw value:32767·LSB=800,0%); USS-Adr: 04 12 80 00 hex
264Ah 0h
D75
Axis
r=3, w=3
Range control 2 lower limit 1: Range control 2 is defined by parameters D70 to D79. The
result is indicated in D195 to D199.
D75 determines the first lower limit of range control. D196 indicates when this limit has been
dropped below and signals that the value in D79 is approaching the critical limit D74. When the
value in D79 is between D75 and D76, this is indicated by D197.
Value range in %: -800.0 ... -50,0 ... 800.0
Fieldbus: 1LSB=0,1%; Type: I16; (raw value:32767·LSB=800,0%); USS-Adr: 04 12 C0 00 hex
264Bh 0h
D76
Axis
r=3, w=3
Range control 2 upper limit 1: Range control 2 is defined by parameters D70 to D79. The
result is indicated in D195 to D199.
D76 determines the first lower limit of range control. D198 indicates when this limit has been
dropped above and signals that the value in D79 is approaching the critical limit D77. When the
value in D79 is between D75 and D76, this is indicated by D197.
Value range in %: -800.0 ... 50,0 ... 800.0
Fieldbus: 1LSB=0,1%; Type: I16; (raw value:32767·LSB=800,0%); USS-Adr: 04 13 00 00 hex
264Ch 0h
D77
Axis
r=3, w=3
Range control 2 upper limit 2: Range control 2 is defined by parameters D70 to D79. The
result is indicated in D195 to D199.
D77 determines the lower limit of range control. If D79 drops above this limit, the display occurs in
D199 and event 63 is triggered. The level of the event can be set in U130 to U132.
Value range in %: -800.0 ... 100,0 ... 800.0
Fieldbus: 1LSB=0,1%; Type: I16; (raw value:32767·LSB=800,0%); USS-Adr: 04 13 40 00 hex
264Dh 0h
D78
Axis
r=3, w=3
Range control 2 Accel + Enable: Range control 2 is defined by parameters D70 to D79. The
result is indicated in D195 to D199.
D78 can be used to restrict range control to static operation. When 0:inactive is parameterized,
range control is not performed during acceleration procedures or when the enable is switched off.
The result signals D195 to D199 are set to 0:inactive. When D78 is parameterized to 1:active,
range control is performed continuously and D195 to D199 are set accordingly.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 13 80 00 hex
264Eh 0h