Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-146
D.. Reference Value
Par. Description Fieldbus-
address
D56
Axis
r=1, w=2
Rated unit speed: Parameter D56 is considered the value of reference for all percental
reference values of the "comfort reference value" application.
NOTE
This parameter is indicated in user units. The user units are specified in D87 and D88.
Value range in D89: 0 ... 3000 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 0E 00 00 hex
2638h 0h
D57
Axis, OFF
r=2, w=2
Inverting motor direction: The motor direction can be inverted with D57. This parameter can
be used to view the reference value sign, regardless of the direction of the motor. An inversion with
D57 also changes the mounting position of the motor or the number of stages of a gearbox.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 0E 40 00 hex
2639h 0h
D60
Axis
r=3, w=3
Range control 1 source: Range control 1 is defined by parameters D60 to D69. The result is
indicated in D190 to D194.
The parameter to be controlled is entered in D60.
NOTE
Only parameters with the data format I16 can be controlled. If you want to control a speed value in
the format I32, the format must first be changed with the parameters D98.X and D99.X.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 04 0F 00 00 hex
263Ch 0h
D61
Axis
r=3, w=3
Range control 1 factor: Range control 1 is defined by parameters D60 to D69. The result is
indicated in D190 to D194.
The parameter entered in D60 can be weighted in D61. An entry of 25% corresponds to a factor of 1.
Value range in %: -800.0 ... 25,0 ... 800.0
Fieldbus: 1LSB=0,1%; Type: I16; (raw value:32767·LSB=800,0%); USS-Adr: 04 0F 40 00 hex
263Dh 0h
D62
Axis
r=3, w=3
Range control 1 low pass filter: Range control 1 is defined by parameters D60 to D69. The
result is indicated in D190 to D194.
The value of the parameter entered in D60 is weighted with the factor D61. Low pass filtering takes
place afterwards. D62 specifies the filter time constants of the low pass.
Value range in ms: 0.0 ... 1,2 ... 200.1
Fieldbus: 1LSB=0,1ms; Type: I32; raw value:1LSB=Fnct.no.11; USS-Adr: 04 0F 80 00 hex
263Eh 0h
D63
Axis
r=3, w=3
Range control 1 mode: Range control 1 is defined by parameters D60 to D69. The result is
indicated in D190 to D194.
D63 determines how the value entered in D69 will be controlled. When D63 is set to 0:range, the
limits are evaluated unchanged. When D64 = -50% and D67 = 60% are parameterized, the valid
working range in this case is between -50% and 60%. Values under -50% or over +60% will cause
the result 60 or 61.
With1:absolute the limits specified in D64 to D67 are evaluated symmetrically to zero. When D64 =
50% and D67 = 60% are parameterized, the valid working range is between +50% to +60% or -60%
and -50%. A value of the controlled parameter outside these ranges will cause the result 60 or 61.
0: range;
1: absolute;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 0F C0 00 hex
263Fh 0h
D64
Axis
r=3, w=3
Range control 1 lower limit 2: Range control 1 is defined by parameters D60 to D69. The
result is indicated in D190 to D194.
D64 determines the lower limit of range control. If D69 drops below this limit, the display occurs in
D190 and event 60 is triggered. The level of the event can be set in U100 to U102.
Value range in %: -800.0 ... -100,0 ... 800.0
Fieldbus: 1LSB=0,1%; Type: I16; (raw value:32767·LSB=800,0%); USS-Adr: 04 10 00 00 hex
2640h 0h