Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-142
D.. Reference Value
Par. Description Fieldbus-
address
D42
Axis
r=1, w=2
Motorised pot ramp 2: The ramps of the motorized pot reference value can be used in two
ways, depending on parameter D40 bit7:
When the bit is 0:inactive, D41 is used as the acceleration ramp and D42 is used as the
deceleration ramp.
When the bit is activated, D41 and D42 are used for acceleration and deceleration. A binary
signal (setting of the signal source in D117) is used to switch between D41 and D42.
This makes it possible to approach the motorized pot reference value area with a fast ramp. After
the switch to the second (lower) ramp, the motorized pot reference value can be adjusted for
more sensitivity.
NOTE
This parameter is indicated in user units per second. The user units are specified in D87 and D88.
Value range in D249: 0 ... 100 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 0A 80 00 hex
262Ah 0h
D43
Axis
r=1, w=2
Motorised pot step value: Parameter D43 is used to set how the signals "motorized pot UP"
and "motorized pot DOWN" are to affect the motorized pot reference signal. When the value 0 is
entered, the reference value is changed with the ramps entered in D41 and D42. This change is
continuous as long as one of the signals "motorized pot UP" or "motorized pot DOWN" is active.
When a value other than 0 is parameterized, the reference value is changed in steps. This step has
the value entered in D43. The step is executed when a positive edge of the signal "motorized pot
UP" or "motorized pot DOWN" occurs. A further edge is not evaluated until the current step is
concluded.
NOTE
This parameter is indicated in user units. The user units are specified in D87 and D88.
Value range in D89: -17 Bit ... 0 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 0A C0 00 hex
262Bh 0h
D44
Axis
r=1, w=2
Motorised pot preset value: The motorized pot reference value can be set to the value in D44
depending on one or more conditions. Setting is executed as per the setting in D40.
NOTE
This parameter is indicated in user units. The user units are specified in D87 and D88.
Value range in D89: -17 Bit ... 0 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 0B 00 00 hex
262Ch 0h
D45
Axis
r=1, w=2
Motorised pot upper limit: When it reaches the value in D45, the motorized pot reference
value is limited to this value unless an adding or multiplying reference value has been used before
and the reference value limits were already reached. When the motorized pot reference value drops
again, the change takes effect immediately.
NOTE
This parameter is indicated in user units. The user units are specified in D87 and D88.
Value range in D89: -17 Bit ... 3000 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 0B 40 00 hex
262Dh 0h
D46
Axis
r=1, w=2
Motorised pot lower limit: When it reaches the value in D46, the motorized pot reference
value is limited to this value. When the motorized pot reference value increases again, the change
takes effect immediately.
NOTE
This parameter is indicated in user units. The user units are specified in D87 and D88.
Value range in D89: -17 Bit ... -3000 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 0B 80 00 hex
262Eh 0h