11. Used Parameters
KSW-139
D.. Reference Value
Par. Description Fieldbus-
address
D27.0
Axis
r=1, w=2
Fix value: A fixed value is defined by D26.X and D27.X. The value of the fixed value (e.g., 1500
rpm) is entered in D27.X. Fixed values can only be used as adding and multiplying reference values
(D31 or D33). When they are used for percental adding (D32 = 1: percentage of D56 ) or
multiplying, they refer to the parameter D56.
NOTE
This parameter is indicated in user units. The user units are specified in D87 and D88.
Value range in D89: -17 Bit ... 0 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 06 C0 00 hex
261Bh
Array
0h
D27.1
Axis
r=1, w=2
Fix value
Value range in D89: -17 Bit ... 0 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 06 C0 01 hex
261Bh
Array
1h
D27.2
Axis
r=1, w=2
Fix value
Value range in D89: -17 Bit ... 0 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 06 C0 02 hex
261Bh
Array
2h
D27.3
Axis
r=1, w=2
Fix value
Value range in D89: -17 Bit ... 0 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 06 C0 03 hex
261Bh
Array
3h
D27.4
Axis
r=1, w=2
Fix value
Value range in D89: -17 Bit ... 0 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 06 C0 04 hex
261Bh
Array
4h
D27.5
Axis
r=1, w=2
Fix value
Value range in D89: -17 Bit ... 0 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 06 C0 05 hex
261Bh
Array
5h
D27.6
Axis
r=1, w=2
Fix value
Value range in D89: -17 Bit ... 0 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 06 C0 06 hex
261Bh
Array
6h
D27.7
Axis
r=1, w=2
Fix value
Value range in D89: -17 Bit ... 0 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 06 C0 07 hex
261Bh
Array
7h
D28
Axis
r=1, w=2
Jog ramp: D28 specifies the ramp of the jog reference value.
NOTE
This parameter is indicated in user units per second. The user units are specified in D87 and D88.
Value range in D249: 0 ... 500 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 07 00 00 hex
261Ch 0h