4. Representing the Reference Values in User Units
KSW-12
4.3 Switching between the Speed/Torque Reference Value
Information that you will find in
this section …
This section explains how to scale reference values after you have activated the switch
between speed and torque reference value (Umschaltung Drehzahl-/Momentsollwert) on
page 1 of the Assistant.
Scaling the reference value
Figure 4-7 shows page 2.3 of the Assistant. You can only scale this type of reference
value in % which means that you don't need to do extensive scaling for speed and torque
mode.
Proceed as shown below:
• In D86 specify the number of decimal digits with which speeds are to be represented.
• Enter "%" in D89.
• Enter 100% in D56.
• Enter a percentage in D87 and parameterize the appropriate speed in D88.
Example:
D87= 50%, D88 = 1000
This gives you a reference value of 50% of a speed of 1000 Rpm.
Figure 4-7 Scaling for reference value type "speed/torque switchover"