Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-135
D.. Reference Value
Par. Description Fieldbus-
address
D23.8
Axis
r=1, w=2
Preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 08 hex
2617h
Array
8h
D23.9
Axis
r=1, w=2
Preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 09 hex
2617h
Array
9h
D23.10
Axis
r=1, w=2
Preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 0A hex
2617h
Array
000
Ah
D23.11
Axis
r=1, w=2
Preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 0B hex
2617h
Array
000
Bh
D23.12
Axis
r=1, w=2
Preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 0C hex
2617h
Array
000
Ch
D23.13
Axis
r=1, w=2
Preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 0D hex
2617h
Array
000
Dh
D23.14
Axis
r=1, w=2
Preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 0E hex
2617h
Array
000
Eh
D23.15
Axis
r=1, w=2
Preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 0F hex
2617h
Array
000
Fh
D24.0
Axis
r=1, w=2
Preset accel left: A ramp profile is defined by parameters D20.X to D25.X. The acceleration
ramp for counterclockwise or negative reference value is entered in D24.X. When D21.X is set to
1:active, D24.X is not used.
NOTE
This parameter is indicated in user units per second. The user units are specified in D87 and D88.
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 06 00 00 hex
2618h
Array
0h
D24.1
Axis
r=1, w=2
Preset accel left
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 06 00 01 hex
2618h
Array
1h
D24.2
Axis
r=1, w=2
Preset accel left
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 06 00 02 hex
2618h
Array
2h
D24.3
Axis
r=1, w=2
Preset accel left
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 06 00 03 hex
2618h
Array
3h