Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-134
D.. Reference Value
Par. Description Fieldbus-
address
D22.12
Axis
r=1, w=2
Preset accel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 80 0C hex
2616h
Array
000
Ch
D22.13
Axis
r=1, w=2
Preset accel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 80 0D hex
2616h
Array
000
Dh
D22.14
Axis
r=1, w=2
Preset accel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 80 0E hex
2616h
Array
000
Eh
D22.15
Axis
r=1, w=2
Preset accel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 80 0F hex
2616h
Array
000
Fh
D23.0
Axis
r=1, w=2
Preset decel right: A ramp profile is defined by parameters D20.X to D25.X. The deceleration
ramp for clockwise or positive reference value is entered in D23.X. When D21.X is set to 1:active,
D23.X is used for clockwise and counterclockwise.
NOTE
This parameter is indicated in user units per second. The user units are specified in D87 and D88.
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 00 hex
2617h
Array
0h
D23.1
Axis
r=1, w=2
Preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 01 hex
2617h
Array
1h
D23.2
Axis
r=1, w=2
Preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 02 hex
2617h
Array
2h
D23.3
Axis
r=1, w=2
Preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 03 hex
2617h
Array
3h
D23.4
Axis
r=1, w=2
Preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 04 hex
2617h
Array
4h
D23.5
Axis
r=1, w=2
Preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 05 hex
2617h
Array
5h
D23.6
Axis
r=1, w=2
preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 06 hex
2617h
Array
6h
D23.7
Axis
r=1, w=2
Preset decel right
Value range in D249: 0 ... 3000 ... 131072000
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 05 C0 07 hex
2617h
Array
7h