Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-131
D.. Reference Value
Par. Description Fieldbus-
address
D20.8
Axis
r=0, w=2
Preset ramp name
Default setting: Ramp 08
Fieldbus: Type: Str16; USS-Adr: 04 05 00 08 hex
2614h
Array
8h
D20.9
Axis
r=0, w=2
Preset ramp name
Default setting: Ramp 09
Fieldbus: Type: Str16; USS-Adr: 04 05 00 09 hex
2614h
Array
9h
D20.10
Axis
r=0, w=2
Preset ramp name
Default setting: Ramp 10
Fieldbus: Type: Str16; USS-Adr: 04 05 00 0A hex
2614h
Array
000
Ah
D20.11
Axis
r=0, w=2
Preset ramp name
Default setting: Ramp 11
Fieldbus: Type: Str16; USS-Adr: 04 05 00 0B hex
2614h
Array
000
Bh
D20.12
Axis
r=0, w=2
Preset ramp name
Default setting: Ramp 12
Fieldbus: Type: Str16; USS-Adr: 04 05 00 0C hex
2614h
Array
000
Ch
D20.13
Axis
r=0, w=2
Preset ramp name
Default setting: Ramp 13
Fieldbus: Type: Str16; USS-Adr: 04 05 00 0D hex
2614h
Array
000
Dh
D20.14
Axis
r=0, w=2
Preset ramp name
Default setting: Ramp 14
Fieldbus: Type: Str16; USS-Adr: 04 05 00 0E hex
2614h
Array
000
Eh
D20.15
Axis
r=0, w=2
preset ramp name
Default setting: Ramp 15
Fieldbus: Type: Str16; USS-Adr: 04 05 00 0F hex
2614h
Array
000
Fh
D21.0
Axis
r=1, w=2
Preset ramp symmetric: A ramp profile is defined by parameters D20.X to D25.X. D21.X
determines whether the same ramps apply to clockwise and counterclockwise. When the setting
0:inactive is used, D22.X and D23.X are used for clockwise and D24.X and D25.X for
counterclockwise. When D21.X is set to1:active, D22.X and D23.X are used independently of the
direction of rotation.
Value range: 0 ... 0: inactive ... 1
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 05 40 00 hex
2615h
Array
0h
D21.1
Axis
r=1, w=2
Preset ramp symmetric
Value range: 0 ... 0: inactive ... 1
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 05 40 01 hex
2615h
Array
1h
D21.2
Axis
r=1, w=2
Preset ramp symmetric
Value range: 0 ... 0: inactive ... 1
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 05 40 02 hex
2615h
Array
2h
D21.3
Axis
r=1, w=2
Preset ramp symmetric
Value range: 0 ... 0: inactive ... 1
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 05 40 03 hex
2615h
Array
3h