11. Used Parameters
KSW-128
D.. Reference Value
Par. Description Fieldbus-
address
D11.6
Axis
r=1, w=2
Preset reference
Value range in D89: -17 Bit ... 1200 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 02 C0 06 hex
260Bh
Array
6h
D11.7
Axis
r=1, w=2
Preset reference
Value range in D89: -17 Bit ... 1400 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 02 C0 07 hex
260Bh
Array
7h
D11.8
Axis
r=1, w=2
Preset reference
Value range in D89: -17 Bit ... 1600 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 02 C0 08 hex
260Bh
Array
8h
D11.9
Axis
r=1, w=2
Preset reference
Value range in D89: -17 Bit ... 1800 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 02 C0 09 hex
260Bh
Array
9h
D11.10
Axis
r=1, w=2
Preset reference
Value range in D89: -17 Bit ... 2000 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 02 C0 0A hex
260Bh
Array
000
Ah
D11.11
Axis
r=1, w=2
Preset reference
Value range in D89: -17 Bit ... 2200 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 02 C0 0B hex
260Bh
Array
000
Bh
D11.12
Axis
r=1, w=2
Preset reference
Value range in D89: -17 Bit ... 2400 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 02 C0 0C hex
260Bh
Array
000
Ch
D11.13
Axis
r=1, w=2
Preset reference
Value range in D89: -17 Bit ... 2600 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 02 C0 0D hex
260Bh
Array
000
Dh
D11.14
Axis
r=1, w=2
Preset reference
Value range in D89: -17 Bit ... 2800 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 02 C0 0E hex
260Bh
Array
000
Eh
D11.15
Axis
r=1, w=2
Preset reference
Value range in D89: -17 Bit ... 3000 ... 17 Bit
Fieldbus: 1LSB=siehe D86; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 02 C0 0F hex
260Bh
Array
000
Fh
D12.0
Axis
r=1, w=2
Preset ramp: Parameters D10.X, D11.X and D12.X define a preset reference value. A preset
reference value is linked to a ramp profile in D12.X. This setting does not take effect unless D13 =
1:Ramp profile is parameterized.
Value range: 0 ... 0 ... 15
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 03 00 00 hex
260Ch
Array
0h
D12.1
Axis
r=1, w=2
Preset ramp
Value range: 0 ... 1 ... 15
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 03 00 01 hex
260Ch
Array
1h