Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-124
C.. Machine
Par. Description Fieldbus-
address
C132
Axis, OFF
r=2, w=2
Torque limit motoring source: In contrast to absolute torque limitation, a maximum motor
and generator torque can be specified with speed control. The source of the maximum motor torque
is selected in C132. C232 is read in the setting 4:parameter. This parameter can be written in
fieldbus mode.
The current value of the signal torque limit motoring can be viewed in C332 regardless of the
selected source.
NOTE
The motor and generator torque limitation is active when the display parameters C332 and C333
have a value other than zero.
0: 0 (zero);
1: AE1;
2: AE2;
3: AE3;
4: parameter;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 03 21 00 00 hex
2484h 0h
C133
Axis, OFF
r=2, w=2
Torque limit generating source: In contrast to absolute torque limitation, a maximum motor
and generator torque can be specified with speed control. The source of the maximum generator
torque is selected in C133. C233 is read in the setting 4:parameter. This parameter can be written
in fieldbus mode.
The current value of the signal torque limit generating can be viewed in C333 regardless of the
selected source.
NOTE
The motor and generator torque limitation is active when the display parameters C332 and C333
have a value other than zero.
0: 0 (zero);
1: AE1;
2: AE2;
3: AE3;
4: parameter;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 03 21 40 00 hex
2485h 0h
C230
Global
r=2, w=2
Torque limit: Specification for the torque limit (absolute value) via fieldbus if the signal source is
C130=4:Parameter.
Value range in %: -200 ... 150 ... 200
Fieldbus: 1LSB=1%; PDO ; Type: I16; (raw value:32767·LSB=200%); USS-Adr: 03 39 80 00 hex
24E6h 0h
C231
Global
r=2, w=2
Torque limit 2: When an absolute torque limit is used, torque limit 2 is used as the second limit.
When a binary signal (D110) is used, you can switch between the sources selected in C130 and
C131 and a hard startup can be implemented.
The parameter C231 is used as the source with the setting C131 = 4:parameter. It can be written
via fieldbus.
The current value of the signal can be viewed in C331 regardless of the selected source.
Value range in %: -200 ... 200 ... 200
Fieldbus: 1LSB=1%; PDO ; Type: I16; (raw value:32767·LSB=200%); USS-Adr: 03 39 C0 00 hex
24E7h 0h
C232
Global
r=2, w=2
Torque limit motoring: In contrast to absolute torque limitation, a maximum motor and
generator torque can be specified with speed control. C232 is read with the setting C132 =
4:Parameter. This parameter can be written in fieldbus mode.
The current value of the signal torque limit motoring can be viewed in C332 regardless of the
selected source.
NOTE
The motor and generator torque limitation is active when the display parameters C332 and C333
have a value other than zero.
Value range in %: 0 ... 150 ... 200
Fieldbus: 1LSB=1%; Type: I16; (raw value:32767·LSB=200%); USS-Adr: 03 3A 00 00 hex
24E8h 0h