Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-117
B.. Motor
Par. Description Fieldbus-
address
B53
Axis, OFF
r=2, w=2
Stator winding resistance: Stator winding resistance Ru-v of the motor winding in ohm. Enter
only for external motors. The value can be autotuned with the B41 action.
Value range in Ohm: 0.001 ... 10,300 ... 2147483.647
Fieldbus: 1LSB=0,001Ohm; Type: I32; USS-Adr: 02 0D 40 00 hex
2235h 0h
B54
Axis, OFF
r=3, w=3
Leakage factor: Ratio of leakage inductance to total inductance "Ls" of the motor
NOTE
The default value is sufficient for most motors and applications. Adjustments may become
necessary when an external motor is connected. In such cases the value can be autotuned with the
action B41. However, do not make this adjustment before consulting with STÖBER
ANTRIEBSTECHNIK GmbH & Co. KG.
Value range: 0.010 ... 0,100 ... 0.300
Fieldbus: 1LSB=0,001; Type: I16; USS-Adr: 02 0D 80 00 hex
1 Only with asynchronous machines (B20 less than 64:Servo-control).
2236h 0h
B55
Axis, OFF
r=3, w=3
Magnetic saturation coefficient: The parameter specifies how much the motor is
magnetically saturated at the nominal point. The parameter is important for the control accuracy of
control type VC (B20=2:VC) in the field weakening area.
NOTE
The default value is sufficient for most motors and applications. Adjustments may become
necessary when an external motor is connected. In such cases the value can be autotuned with the
action B41. However, do not make this adjustment before consulting with STÖBER
ANTRIEBSTECHNIK GmbH & Co. KG.
Value range: 0.000 ... 0,750 ... 0.950
Fieldbus: 1LSB=0,001; Type: I32; (raw value:2147483647 = 32767.000); USS-Adr: 02 0D C0 00 hex
1 Only with asynchronous machines (B20 less than 64:Servo-control).
2237h 0h
B61
Axis, OFF
r=2, w=2
T-Motor (thermal): Time constant of motor heatup in seconds.
Value range in s: 0.1 ... 1040,0 ... 3276.7
Fieldbus: 1LSB=0,1s; Type: I16; USS-Adr: 02 0F 40 00 hex
223Dh 0h
B62
Axis, OFF
r=2, w=2
Motor inertia: Inertia J of the motor in kg cm².
Value range in kg cm2: 0.0001 ... 0,4151 ... 214748.3647
Fieldbus: 1LSB=0,0001kg cm2; Type: I32; (raw value:1LSB=0,0001); USS-Adr: 02 0F 80 00 hex
223Eh 0h
B63
Axis, OFF
r=3, w=3
Mmax/Mnom: Relationship of breakdown torque of the motor to its nominal torque.
Value range: 1.0 ... 2,5 ... 8.0
Fieldbus: 1LSB=0,1; Type: I16; (raw value:32767 = 8.0); USS-Adr: 02 0F C0 00 hex
1 Only with asynchronous machines (B20 less than 64:Servo-control).
223Fh 0h
B64
Axis
r=3, w=3
Integral time lq: Integral time of the current controller for the torque-generating share in msec. A
setting under 0.6 msec causes an integral gain of 0 (corresponds to an infinite integral time).
Value range in ms: 0.0 ... 1,4 ... 100.0
Fieldbus: 1LSB=0,1ms; Type: I16; USS-Adr: 02 10 00 00 hex
1 Only with control types with current control (B20 = 64:Servo or 2:VC).
2240h 0h
B65
Axis
r=3, w=3
Proportional gain torque controller: Proportional gain of the torque controller.
Value range in %: 0.0 ... 50,0 ... 800.0
Fieldbus: 1LSB=0,1%; Type: I16; (raw value:32767·LSB=800,0%); USS-Adr: 02 10 40 00 hex
1 Only with control types with current control (B20 = 64:Servo or 2:VC).
2241h 0h