11. Used Parameters
KSW-112
B.. Motor
Par. Description Fieldbus-
address
B17
Axis, OFF
r=1, w=1
T0 (standstill): Standstill torque M0 as per nameplate. Used, among others, as reference value
for the torque and current limitation (C03 and C05).
Value range in Nm: 0.000 ... 1,410 ... 2147483.647
Fieldbus: 1LSB=0,001Nm; Type: I32; USS-Adr: 02 04 40 00 hex
1 Only with servo operation (B20 greater or equal to 64:Servo-control).
2211h 0h
B18
Axis
read (3)
Related torque: The parameter B18 shows the reference value for percentage of torque values
(such as C03, C05, E62 and E66) in every control mode (B20).
Value range in Nm: -11.28 ... 1,41 ... 11.28
Fieldbus: 1LSB=0,01Nm; Type: I16; raw value:1LSB=Fnct.no.22; USS-Adr: 02 04 80 00 hex
2212h 0h
B19
Axis, OFF
r=1, w=1
cos (phi): Cos (phi) as per nameplate.
Value range: 0.500 ... 0,720 ... 1.000
Fieldbus: 1LSB=0,001; Type: I16; USS-Adr: 02 04 C0 00 hex
1 Only with asynchronous machines (B20 less than 64:Servo-control).
2213h 0h
B20
Axis, OFF
r=3, w=3
Control mode: Specifies the type of motor control.
NOTE
- With control type "0: V/f-control," there is no current or torque limitation. Similarly, connection to a
rotating motor is not possible ("capturing").
- Control type 64:Servo-control is not available with the FDS 5000 inverter.
0: V/f-control; Simplest type of control for the asynchronous machine (ASM). The corresponding
reference value frequency and voltage are calculated from the specified speed and rigidly
applied to the motor.
1: Sensorless vector control;
2: Vector control;
64: Servo-control
; Type of control for servo drives.
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 02 05 00 00 hex
2214h 0h
B21
Axis, OFF
r=1, w=1
V/f-characteristic: Switch between linear and square characteristic curve.
0: Linear; Voltage/frequency characteristic curve is linear. Suitable for all applications.
1: Square; Square characteristic curve for use with fans and pumps. The characteristic curve is
continued linearly starting at the nominal frequency (B15).
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 02 05 40 00 hex
1 Only with asynchronous machines (B20 less than 64:Servo-control).
2215h 0h
B22
Axis
r=1, w=1
V/f-factor: Offset factor for the increase of the V/f characteristic curve. The increase with V/F
factor = 100% is specified by V-nominal (B14) and f-nominal (B15).
Value range in %: 90 ... 100 ... 110
Fieldbus: 1LSB=1%; Type: I16; (raw value:32767·LSB=800%); USS-Adr: 02 05 80 00 hex
1 Only with asynchronous machines (B20 less than 64:Servo-control).
2216h 0h
B23
Axis
r=1, w=1
V/f-Boost: The term boost means an increase in voltage in the lower speed range whereby a
higher startup torque is available. With a boost of 100% the nominal motor current flows at 0 Hz. To
specify the required boost voltage, the stator resistance of the motor must be known.
For this reason, with motors without electronic nameplate, it is essential that B41 (autotune motor)
be performed!!
With STÖBER standard motors, the stator resistance of the motor is specified by the choice of
motor.
Value range in %: 0 ... 10 ... 400
Fieldbus: 1LSB=1%; Type: I16; (raw value:32767·LSB=800%); USS-Adr: 02 05 C0 00 hex
1 Only with V/f control (B20=0).
2217h 0h