Operating instructions

10 309424
Spray tips have 4 or 5digit numbers on them.
The first two digits are the spray angle. Tip
holding holes are provided on the chassis
including one extra hole for future tip placement.
1. Perform Pressure Relief Procedure, page 5.
2. Point the gun and wand away from you and anyone else.
3. Without holding your hand over spray tip (A), pull back quick
coupler ring (B). Remove the current tip, install a different
one. Then push the ring back on.
Installing and Changing Spray Tips
Spray Tip
Number
Spray Pattern Fan Angle
00XXX
15XXX
40XXX
Chemical
0_ blaster (red)
15_ (yellow)
40_ (white)
XX_ (black)
NOTE: The chemical injector tip is brass and has a large opening and a black plastic cap.
B
A
To avoid blowing the oring out of the quick
coupler due to high pressure in system, never
operate Zip Clean without a tip securely mounted
in quick coupler.
CAUTION