Product manual

EAP01 - Product Manual
Table 3 EAP01 Faults – Intellevac Units (ACU and DAU), VAR8, and VAR8-ACU
Operational Fault
Symptom
Fault
Description
Fault Code(s)
Reported and
Logged at the
Intellevac Units/
VAR8/VAR8-ACU
Other
Indication
Suggested Action
Total loss of live
audio announcement
from a single
microphone, though
the microphone still
appears to be
functional.
Input audio
surveillance
IPXX AUDIO INPUT
XX=01 to 08
Mic Status LED
constantly ON
or OFF
Check audio cabling or power
supply cabling between
microphone and Router.
Replace microphone console.
Replace Router.
Total loss of live
audio announcement
from a single
microphone, though
the microphone still
appears to be
functional.
Mic capsule
fault
MIC<n> MIC
CAPSULE
n=01 to 08
Mic Status LED
constantly ON
or OFF
Check continuity of microphone
capsule and any associated
wiring, if faulty then replace
capsule if possible.
Replace microphone console.
Replace Router.
Total loss of all
functionality on a
single microphone.
Mic comms
fault
MIC<n> MIC COMMS
n=01 to 08
Mic Status LED
constantly ON
or OFF
Check data cabling or power
supply cabling between
microphone and Router.
Replace microphone console.
Replace Router.
No operational
failure on initial fault
report. Total loss of
all functionality on a
single microphone if
subsequent fault
reports within one
hour.
Mic CPU
reset
MIC<n> MIC COMMS
n=01 to 08
Mic Status LED
constantly ON
or OFF
A one-off occurrence may be
experienced due to EMI or
transients.
Repeated occurrences indicate
faulty microphone electronics,
so replace microphone
console.
Total loss of all
functionality on a
single microphone.
Mic RAM
error
MIC<n> FAULT 09
n=01 to 08
(Mic Processor stops)
Mic Status LED
constantly ON
or OFF
A one-off occurrence may be
experienced due to EMI or
transients.
Repeated occurrences indicate
faulty microphone electronics,
so replace microphone
console.
Total loss of all
functionality on a
single microphone.
Mic ROM
error
MIC<n> FAULT 09
n=01 to 08
(Mic Processor stops)
Mic Status LED
constantly ON
or OFF
Replace microphone console.
Loss of All-Call
functionality on a
single EAP01
microphone
All Call PTT
Contact
Fault
IP01 ALLCALL PTT
Audio Input 01
or
IP02 ALLCALL PTT
Audio Input 02
Check hardwired PTT wiring
between the appropriate
microphone and the Router.
Replace microphone console.
Replace Router.
Loss of Speak Now
LED functionality on
a single EAP01
microphone
LED fault
SPEAK-
NOW
IP01 SPEAK LED
Audio Input 01
or
IP02 SPEAK LED
Audio Input 02
Check wiring between Router
and SPEAK-NOW LEDs on the
appropriate microphone.
Replace microphone console.
Replace Router.
Issue: 02 complete, approved
Page 35 of 52