3.2 Installation Requirements
3.2.1 Equipment and Tool Requirements
The EAP01 unit.
Suitable cable glands/conduit fixings, preferably with cable screen earthing facilities.
A small flat bladed screwdriver.
A 2.5 mm Allen key or driver.
A pozidriv screwdriver (No 1).
Suitable wire cutters, strippers and cable ferrules.
A drill with bits and hole cutters suitable for cutting 2 mm mild steel, for the back box mounting holes and
cable glands.
Suitable fixings and tools for wall mounting.
Sealant.
3.2.2 Cabling Requirements
3.2.2.1 Cabling to a VAR Router
Signals Cable Description Suggested Type
Audio 1 x 2 core, twisted, screened, 1.0 mm
Low Smoke and Fume (LSF).
For BS5839 Pt 8 compliance fire rated cable
(Firecell for example) must be used.
Data
(for Busy indicator, optional)
1 x 2 core, twisted, screened, 1.0 mm
Low Smoke and Fume (LSF).
For BS5839 Pt 8 compliance fire rated cable
(Firecell for example) must be used.
Power 1 x 2 core, screened, 1.0 mm
Low Smoke and Fume (LSF).
For BS5839 Pt 8 compliance fire rated cable
(Firecell for example) must be used.
Other Signals 1 x 6 core, screened, 1.0 mm
Low Smoke and Fume (LSF).
For BS5839 Pt 8 compliance fire rated cable
(Firecell for example) must be used.
L
For cable-run limitations and alternative cable types, please refer to Application Solutions (Safety and
Security) Ltd. for advice.
!
!
For EMC compliance:
Screened cables must be used where specified.
All field cable screens must be connected to the back box.
All screen tails must be <3 cm.
3.2.2.2 Cabling to a wall-mount Intellevac DAU or ACU
Please refer to the Intellevac System Installation Guides; see Table 5 (page 48).