Service manual

Fault indicators TD70.3
In the case of a fault the following fault indicators are shown on the LCD display.
Troubleshooting
S1 S3LCD1 LCD2 LCD3
J1 S2
LCD Cause Action
Overow fault, Overflow
Fault, Over flow fault,
Överfyllnad, Overløbsfejl,
Overflom, Ylitulviminen, Trop
plein, Überlauf, Troppo pieno,
Desborde, Пeрeлив вoды, Te
veel water
The microswitch is opened when a full
condensed water tank is detected. Detection
begins 30 seconds after the program starts.
If the microswitch is open >30 seconds the
program cycle is stopped.
Check whether the customer has:
Emptied the tank and restarted the
machine.
Service action:
Clean hoses and check drainage pump
voltage and resistance.
Check that theoat has not got “stuck and
check the function of the microswitch.
Max Program Time, Max
program time, Maximal
programtid, Maksimal
programtid, Maks programtid,
Max ohjelma-aika, Durée
maxi prog., Tijd overschreden,
Tempo max. progr., Duración
máx prog, Пpeвышeниe
вpeмeни, Max. Programmzeit
The program cycle time exceeds 200 minutes.
The cycle is stopped and the program is reset.
High ambient temperature combined with low
heater output and low drying temperature leads
to poor condensation formation.
Poor condensation due to blocked external air
Check whether the customer has:
Tried spinning at a higher speed.
Had the machine switched off for 30
minutes before restarting.
Good ventilation in the room.
Service action:
Ensure that the external air has free
passage.
Thermistor fault, Thermistor
Fault, Thermistor fault,
Termistorfel, Termostat fejl,
Termistor, Termistorivika,
faut, Termistorfehler,
Termistore, Fallo, Teрмист,
Temp. sensor fout
1. Thermistor circuit open
2. Thermistor malfunction
Service action:
Check the thermistor. Replace if necessary.
Clean condenser, Renr
kondensor, Rens kon.
sator, Rens kon.sator,
Puhdista lauhdutin,
Nettoyage condenseur,
Reinigen kondensor, Pulizia
condensatore, Limpiar
condensador, Oчистить
кoндeнсaтoр, Kondenser
reinigen
1. Displayed automatically every 100 cycles.
2. Displayed if the machine has indicated “Clean
filter” twice in a row.
Check whether the customer has:
Cleaned the condenser and thelter.
Cleaned the other air passages.
Clean Lint Filter, Clean Lint
Filter, Renr filtret, Renr
fnugfilter, Rens filter, Puhdista
sihti, Nettoyage filtre, Reinig
filter, Pulizia filtro, Limpie el
filtro, Oчистить фильтp, Sieb
reinigen
Check whether the customer has:
Cleaned the lintlter.
After carrying out corrective actions as above, reset the fault indication on the display by switching off the machine at the
main power switch.
S1 S3
DISPLAY1 DISPLAY2 DISPLAY3
S5 S2
S4
Service Manual TD70
29