Service manual

Indication Cause Action
The light to the left of the
Start button flashes
The microswitch is opened when a
full condensed water tank is detected.
Detection begins 30 seconds after the
program starts. If the microswitch is open
>30 seconds the program cycle is stopped.
Check whether the customer has:
Emptied the tank and restarted the machine.
Service action:
Clean hoses and check drainage pump
voltage and resistance.
Check that theoat has not got “stuck and
check the function of the microswitch.
The light above the Start
buttonashes
The program cycle time exceeds 200
minutes. The cycle is stopped and the
program is reset.
High ambient temperature combined
with low heater output and low drying
temperature leads to poor condensation
formation.
Poor condensation due to blocked
external air
Check whether the customer has:
Tried spinning at a higher speed.
Had the machine switched off for 30 minutes
before restarting.
Good ventilation in the room.
Service action:
Ensure that the external air has free passage.
After carrying out corrective actions as above, reset the fault indication on the display by switching off the machine
at the main power switch.
J1S1 S10
S7S4 S11
L2 L24L9
L7L4
L3 L8
T 7 4 3 C
B U T T E R F L Y D R Y I N G
Auto Normal Dry
Auto Iron Dry
Auto Extra Dry
Auto Dry
L35
L37 L36
L33
L29
L32
L34
Troubleshooting
Fault indicators TD70.1
In the case of a fault the following fault indicators are shown.
LCD Cause Action
F10 is shown on the display The microswitch is opened when a
full condensed water tank is detected.
Detection begins 30 seconds after the
program starts. If the microswitch is open
>30 seconds the program cycle is stopped.
Check whether the customer has:
Emptied the tank and restarted the machine.
Service action:
Clean hoses and check drainage pump
voltage and resistance.
Check that the float has not got “stuck” and
check the function of the microswitch.
F29 flashes on the display Check whether the customer has:
• Cleaned the evaporator filter (net filter
+ foam filter) and the evaporator.
HP
F30 is shown on the display The program cycle time exceeds 200
minutes. The cycle is stopped and the
program is reset.
High ambient temperature combined
with low heater output and low drying
temperature leads to poor condensation
formation.
Poor condensation due to blocked
external air
Check whether the customer has:
Tried spinning at a higher speed.
Had the machine switched off for 30 minutes
before restarting.
Good ventilation in the room.
Service action:
Ensure that the external air has free passage.
After carrying out corrective actions as above, reset the fault indication on the display by switching off the machine at
the main power switch.
/
J1 S9S1 S10
S7S3 S11LCD
L2 L18 L24 L29L9
L7L4
L3 L8
L31S4
Panel type A
Panel type B
Service Manual TD70