Service Manual Tumble Dryer - TD70
Service Manual Contents Tumble Dryer TD70 Updates...................................................................................................................................................................................................................................................4 Introduction............................................................................................................................................................................................................
Service Manual TD70 Updates Rev Date Description Initials 01 2011-09-06 First version FH 02 2011-10-03 BRAND OTHER included FH 03 2011-10-20 New document structure FH 04 2012-01-20 New revision circuit diagram EH 05 2012-05-03 Changed the info about Autofilter BPA 06 2012-05-04 Updated part no control units, irrelevant articles deleted. EH 07 2012-07-05 Troubleshooting TD70 HP, LCD F29, removing back rear included.
Service Manual TD70 Introduction You are holding the service manual for TD70 tumble dryers. It should be easy to service a tumble dryer. It is important that you, as a service technician, are provided the necessary conditions to work in an efficient and satisfactory manner. Our hope is that this Service & Training Guide is a useful tool for your daily work.
Service Manual TD70 Troubleshooting strategy Troubleshooting is an important part of the service callout, and as such we have drawn up a troubleshooting strategy that describes, in broad terms and step by step, what you need to do to find and diagnose faults arising in our machines. • Ask the customer to describe the problem. • Check whether the customer’s description matches the reported fault.
Service Manual TD70 Product overview TD70.1, Paneltype A - (BRAND ASKO) S1 S4 S7 S11 J1 Programs: 4 Options: 2 Settings: 1 S10 TD70.1, Paneltype B - (BRAND ASKO) S7 S11 / S1 J1 Programs: 6 Options: 5 Settings: 1 S3 S4 TD70.1 - (BRAND OTHER) S1 6 Options: 5 Settings: 1 S3 TD70.
Service Manual TD70 Product overview TD70.2 - (BRAND OTHER) S1 J1 Programs: 6-15 Options: 5 Settings: 1 TD70.3 S1 DISPLAY DISPLAY1 S2 S3 S8 S9 S4 S5 S6 S7 DISPLAY2 DISPLAY3 J1 S3 S2 Programs: 10, plus settings menu Options: 5 Settings: 4 TD70.
Service Manual TD70 Technical data Technical information Height 850 mm Width 595 mm Depth 585 mm Weight 43 kg (Vented) 47 kg (Condenser) 55 kg (Heat pump) 44 kg (Heating Water Circuit) Cylinder volume 112 litres Capacity EU 7.0 kg US/AU 7.
Service Manual TD70 Component description Components and measurement values The specified resistance values apply at room temperature (about 20°C/68°F). Values within ±10% are considered normal. Article no. Component Measurement value Comment 80 839 15 Motor 50 Hz, 220/240 V 80 839 16 Motor 60 Hz, 220/240 V The motor is a 2-pin motor and is directly connected to the fan for internal air and the gearing for driving the cylinder. On condenser dryers, the motor also drives the fan for external air.
Service Manual TD70 Component description Article no. Component 80 761 03 Microswitch float Overflow guard 80 824 92 80 915 90 Heating element 1950 W Heating element 2500 W Heating element 3000 W Base heat pump complete Base heat pump complete Reversing valve Control unit compl. TD70.1 A Control unit compl. TD70.1 B Control unit complete TD70.2 Control unit complete TD70.2 HP/HWC Control unit complete TD70.3 Control unit complete TD70.3 FI LED-light compl.
Service Manual TD70 Component descriptions Components and function description Here we describe the function and specification of the most important components. Certain components are found only in more highly specified machines or in particular markets. See the Troubleshooting chapter for fault and information codes. CU (Control Unit) The CU (Control Unit) functions as both a control panel and a logic component.
Service Manual TD70 Component descriptions Thermostat Reset Overheating cut-out EMC filter The filter is installed next to the cable fasteners where the connection cable enters the machine. The filter consists of a number of coils, condensers and resistors. Purpose: To eliminate electromagnetic interference to and from the machine. Overflow guard The overflow guard comprises a microswitch triggered by a float.
Service Manual TD70 Component descriptions Door switch The door switch is located in a holder in the middle of the front support and is activated by a pin in the front door. The switch is normally open and closes when the door is closed. If the front door is opened during operation the CU stops the drying program. The program starts from the beginning if restarted. Purpose: To prevent the machine from running while the door is open.
Service Manual TD70 Component descriptions Heat pump (HP) Certain types of machine are fitted with heat pump systems. These systems are closed circuits that are replaced by replacing the machine’s base plate with a new module. The function settings are adjusted in the service menu. 2 1B 1A Heating Water Circuit (HWC) A certain type of machine is adapted for connection to the building’s existing heated water supply (such as district heating) to reduce energy consumption.
Service Manual TD70 Programs and control unit Circuit diagram TD70.
Service Manual TD70 RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F) VALUES WITH +/-10% ARE REGARDED AS NORMAL COMPONENT AT SWITCH F: RADIO INTERFERENCE SUPPRESSION FILTER 680K Ohm NTC 1: THERMISTOR 1 4 - 6 K Ohm NTC 2: THERMISTOR 2: 4 - 6 K Ohm AP: DRAIN PUMP: 111 Ohm EL: HEATING ELEMENT 550W 91.4 Ohm EL: HEATING ELEMENT 1050W 45.3 Ohm EL: HEATING ELEMENT 1950W 20.
Service Manual TD70 Programs and control unit Circuit diagram TD70.
Service Manual TD70 RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F) VALUES WITH +/-10% ARE REGARDED AS NORMAL COMPONENT FLOAT SWITCH F: RADIO INTERFERENCE SUPPRESSION FILTER 680K Ohm NTC 1: THERMISTOR 1 4 - 6 K Ohm NTC 2: THERMISTOR 2: 4 - 6 K Ohm AP: DRAIN PUMP: 111 Ohm EL: HEATING ELEMENT 550W 91.4 Ohm EL: HEATING ELEMENT 1050W 45.3 Ohm EL: HEATING ELEMENT 1950W 20.
Service Manual TD70 Programs and control unit Circuit diagram TD70.
Service Manual TD70 EL SWITCH TCHING VALVE MP, FLOAT SWITCH OMPRESSOR MACHINES E MACHINES RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F) VALUES WITH +/-10% ARE REGARDED AS NORMAL COMPONENT F: RADIO INTERFERENCE SUPPRESSION FILTER 680K Ohm NTC 1: THERMISTOR 1 4 - 6 K Ohm NTC 2: THERMISTOR 2 4 - 6 K Ohm NTC 3: THERMISTOR 3 61 K Ohm AP: DRAIN PUMP: 111 Ohm MO: MOTOR FB: FLOAT SWITCH DB: DOOR SWITCH BE: INTERIOR LIGHT NB: LEVEL REED SWITCH CO: COMPRESSOR SV: SWITCHING VALVE 1.
Service Manual TD70 Programs and control unit Circuit diagram TD70.
Service Manual TD70 RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F) VALUES WITH +/-10% ARE REGARDED AS NORMAL COMPONENT F: RADIO INTERFERENCE SUPPRESSION FILTER 680K Ohm NTC 1: THERMISTOR 1 4 - 6 K Ohm NTC 2: THERMISTOR 2 4 - 6 K Ohm EL: HEATING ELEMENT 1950W 20.
L N L L2 2 L2 2 L1 2 L1 2 N RECG INKB RECL RECL L CONNECTION BOX FOR USA & CANADA *A FB MO AP T1 3 6 4 5 F N T2 EL 550W/ 1050 W TB EL 1950 W 80 902 62 - 02 CIRCUIT DIAGRAM TD70.3 2012-01-11 BE DB WIRES IN ALL MACHINES WIRES IN SOME MACHINES *A CONDENSE DRYER NTC 2 *A This document must not be copied without our written pemission, and the contents thereof must not be imparted to a third party nor be used for any unauthorized purpose. Contravention will be prosecuted.
5 6 Service Manual TD70 T2 T1 CABLE POSITIONS 1: THERMISTOR 4: MOTOR, DRAIN PUMP, FLOAT SWITCH 5: DOOR SWITCH 5: INTERIOR LIGHT TB: POWER EL: HEATING ELEMENT N 3 N6 TB T2 EL 550W/ 1050 W 3 6 TB EL 550W/ 1050 W EL 1950 W RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F) VALUES WITH +/-10% ARE REGARDED AS NORMAL COMPONENT F: RADIO INTERFERENCE SUPPRESSION FILTER 680K Ohm NTC 1: THERMISTOR 1 4 - 6 K Ohm NTC 2: THERMISTOR 2: 4 - 6 K Ohm AP: DRAIN PUMP: 111 Ohm EL: HEATING ELEMENT 550W 91.
Service Manual TD70 Troubleshooting Fault indicators TD70.1 In the case of a fault the following fault indicators are shown. L4 Panel type A L7 Auto Dry S4 S7 Auto Normal Dry S11 L35 T 7 4 3 C S1 L3 L2 J1 L9 L34 L32 Auto Iron Dry Auto Extra Dry L33 L8 L24 L29 B U T T E R F L Y L37 S10 D R Y I N G L36 Indication Cause Action The light to the left of the Start button flashes The microswitch is opened when a full condensed water tank is detected.
Service Manual TD70 Troubleshooting Fault indicators TD70.2 In the case of a fault the following fault indicators are shown on the display. S2 S3 S1 J1 Display Over flow fault, Overflow Fault, Over flow fault, Överfyllnad, Overløbsfejl, Overflom, Ylitulviminen, Trop plein, Überlauf, Troppo pieno, Desborde, Пeрeлив вoды, Te veel water DISPLAY S8 S9 S4 S5 S6 S7 Cause The microswitch is opened when a full condensed water tank is detected. Detection begins 30 seconds after the program starts.
Service Manual TD70 Troubleshooting Fault indicators TD70.2 cont. In the case of a fault the following fault indicators are shown on the display. Display Clean condenser, Rengör kondensor, Rens kon. sator, Rens kon.
Service Manual TD70 Troubleshooting Fault indicators TD70.3 In the case of a fault the following fault indicators are shown on the LCD display. S1 LCD1 LCD2 LCD3 J1 S3 S2 LCD Cause Action Over flow fault, Overflow Fault, Over flow fault, Överfyllnad, Overløbsfejl, Overflom, Ylitulviminen, Trop plein, Überlauf, Troppo pieno, Desborde, Пeрeлив вoды, Te veel water The microswitch is opened when a full condensed water tank is detected. Detection begins 30 seconds after the program starts.
Service Manual TD70 Troubleshooting Other faults If the tumble dryer does not work, you should first check whether this is due to a simple fault, something that the customer can rectify. Fault symptom Cause Action The machine will not start. The outer door is not properly closed. • Check that the door pin is activating the door switch. The machine is not supplied with power. • Check the fuses and connections. The machine stops. The washing does not get dry. Drying is uneven.
Service Manual TD70 Troubleshooting Other faults cont. Cause Action The machine is leaking water. Improper installed auto filter and/or sealing Information to customer: • Check that the auto filter and the sealing is proper installed. Defective auto filter and/or sealing Information to customer: • Handle the auto Filter and sealing carefully when cleaning. Service action: • Replace the auto filter and/or the sealing.
Service Manual TD70 Service menu TD70.1 L4 Auto Dry L7 S4 S7 Auto Normal Dry S11 L35 T 7 4 3 C S1 L3 L2 J1 L9 L34 L32 Auto Iron Dry Auto Extra Dry L33 L8 L24 L29 B U T T E R F L Y L37 S10 D R Y I N G L36 Paneltype A Opening the service menu Auto skåptorrt Auto extratorrt Tidsprogram + T 7 5 3 C Check that the machine is switched off. Otherwise switch off the main power by pressing the main power switch (S1).
Service Manual TD70 Service menu TD70.1 L4 L7 S3 S4 L31 S7 DISPLAY S11 / S1 L3 Paneltype B L2 J1 L9 Opening the service menu Auto skåptorrt Auto extratorrt Tidsprogram L24 L29 S9 S10 Auto normaltorrt Auto stryktorrt Luftningsprogram T 7 5 3 C B U T T E R F L Y D R Y I N G x5 T 7 5 3 C L18 Check that the machine is switched off. Otherwise switch off the main power by pressing the main power switch (S1).
Service Manual TD70 Service menu TD70.2 S1 J1 S2 S3 DISPLAY Opening the service menu Auto skåptorrt Auto extratorrt Tidsprogram B U T T E R F L Y T 7 5 3 C B U T T E R F L Y Turn/ Push D R Y I N G D R Y I N G Turn the program selector (J1) to make selections from the menus. Confirm the selection and continue to the next menu by pressing the Stop button (S9). Press the Start button (S10) to confirm the settings and exit the service menu.
Service Manual TD70 Turn/ Push Display Comments/instructions Dry level Dry level Dry level Dry level Dry level D R Y I N G T 7 5 3 C B U T T E R F L Y D R Y I N G T 7 5 3 C B U T T E R F L Y D R Y I N G Steam Off Steam On Heat Pump Off Heat Pump On Autofilter Off Autofilter On Setting for Steam Off, default setting Setting for Steam On (only machines with steam function) Setting for Heat Pump Off, default setting Setting for Heat Pump On Setting for self-cleaning filter off, default setting
Service Manual TD70 Service menu TD70.3 S1 DISPLAY1 DISPLAY2 DISPLAY3 J1 S3 S2 Opening the service menu (non-integrated) + Check that the machine is switched off. Otherwise switch off the main power by pressing the main power switch. Press and hold the program selector (S1) while turning on the power with the main power switch. × 3 Press the program selector (S1) 3 times within 5 seconds. The service menu is now activated, and is shown in display window 2.
Service Manual TD70 Service menu TD70.3 cont. Turn/ Push Display 2 Comments/instructions DataSerialNo xxxx CU date code xxxx Software 1 xxxxxxxxxx Software 2 xxxxxxxxxx No. of cycles xxxx Date the software was programd (Year_Week) Date of manufacture of the control unit (Year_Week) Software version number Software version number Number of cycles/programs run “Fault_No. of cycles (1)” “Fault_No. of cycles (2)” “Fault_No.
Service Manual TD70 Settings User settings are is described in the machine’s operating instructions. TD70.1 - Total reset To reset the machine to its factory settings: 1. Turn off the main power switch (I/0). 2. Wait at least 5 seconds. 3. Press and hold the Stop button (S11). 4. Switch on the main power switch (I/0). 5. Release the Stop button (S11). TD70.1 - Activating heating element 2 Heating element 2 can be activated/deactivated as follows: 1. Turn off the main power switch (I/0). 2.
Service Manual TD70 Service and installation Dismount top cover and back rear Instructions Illustration 1. Unscrew the top cover. 2. Dismount the panel rear cover by removing the screws and carefully bend in the upper edge. 3. Dismount the heating element by removing the screws and disconnect the cables. 4. Release the nut bearing lock (socket wrench 19). 5. Remove the external fan wheel (socket wrench 10) and unscrew the encircling screws (Torx 10).
Service Manual TD70 Service and installation Dismount top cover and back rear cont. Instructions Illustration 6. Disconnect the rubber hose. 7. Remove the screws on the rear panel (Torx 20). Note! Make sure that the cylinder not fall down.
Service Manual TD70 Service and installation Replacing the panel and the control unit Instructions Illustration 1. Attach the anti-static wristband to a part of the machine that is earthed! NOTE! An anti-static wristband must be used, otherwise you risk destroying the control card. 2. Unscrew the top cover. 2. Carefully press the catches that secure the panel to the front support. Release the catches from the front support by working the panel outwards. 3.
Service Manual TD70 Service and installation Replacing the panel and the control unit Instructions 6. Carefully pull the program selector from the panel. 7. Use a screwdriver to free the control card from the panel. NOTE! The control card must be placed in an ESD-safe bag. 8. Check that the push button, lens and decorative inlay are in place. Now carefully press the new control card into place. 9. Attaching the panel: Attach all wiring to the appropriate connectors on the control card.
Service Manual TD70 Service and installation Transporting a tumble dryer with a heat pump Machines with a heat pump must only be transported upright or placed on the left side when viewed from the front. In extreme cases, laying the machine on any other side, or transporting it in an incorrect manner, may result in making the machine unusable. Let the machine stand for 24 hours after transport before use, otherwise the heat pump may be damaged.
80 925 38 Rev07 2012-07-05 We reserve the right to make changes. www.asko.