Operating instructions

Electrical installation
The electrical wall socket must be placed outside
of the installation area to be easily accessible.
The machine must only be connected to an
earthed wall socket.
If this appliance is supplied from a cord extensions
set or electrical portable outlet device, the cord
extension ser or electrical portable outlet device
must be positioned so that it is not subject to
splashing or ingress of moisture.
Connection on delivery
The machine is supplied as 1-phase, 230V, 50HZ,
heat output 1950W and has a 10A plug. Any
residual current devices must be type A.
Switch-over
It is possible to switch over from 10 A (heat output
1950 W) to 16 A (heat output 2500 W).
The switchover must be performed by a qualified
electrician.
1.
Turn off the machine using the main power
switch.
2.
Press the main power switch and the tempera-
ture selection button at the same time and hold
them for three seconds.
3.
Turn the program selector clockwise until
"Heater 2 on" appears on the display.
4.
Press the Start button to save.
If you want to reset the machine to a 10A connec-
tion:
1.
Repeat steps 1-3.
2.
In step 3, turn the program selector until
"Heater 2 off" appears on the display.
3.
Press the Start button to store the setting.
The machine now has 10A connection.
24
Installation