Technical data

29
Specifications are subject to change without notice. See installation instructions for additional details.
Washer Opening
Vented Dryers
ASKO vented dryers can be vented from the rear or the left or
right side. The cabinet cutout illustrated below gives the
dimensions for a rear or left exhaust.
See page 24 for venting requirements.
WARNING! To reduce the risk of fire, vented dryers must be
exhausted OUTDOORS or the equivalent. See page 24 for venting
requirements.
Never cover the end of the dryer stub or vent hose with anything
to catch lint, except for a UL-approved vent basket.
Condenser Dryers
ASKO condenser dryers can be installed to continuously drain
through a hose attached to the rear of the machine. To ensure
proper drainage, the drain must not be higher than 40"
above the bottom of the dryer.
See page 25 for condensation drain requirements.
ASKOs front panel controls make it possible to install the washers and dryers under a
cabinet or in a closet. Make sure there is a 1/2" (12 mm) minimum clearance between
units and between units and cabinet or wall.
Every ASKO washer is delivered ready-fitted with a plug and is intended for connection to
an ASKO dryer, which is equipped with a matching receptacle. When an ASKO washer is
connected to the dryer, use 220 V, 30 Amp single-phase circuit. When the dryer is on a
separate outlet, use 220 V, 20 Amp single-phase circuit. If the washer is used separately
or with another dryer, it must be on a separate 220 V, 20 Amp single-phase circuit.
Planning & Design: Laundry
SINGLE UNIT CABINET INSTALLATIONS
Cutout Dimensions
US METRIC
HEIGHT 34"35-1/2" 864902 mm
WIDTH 24-1/2"minimum 622 mm
DEPTH 25" 635 mm
NOTE: For these installations, a custom
countertop may be required.
Vented Dryer Opening
Condenser Dryer Opening