Planning & Design: Dryers
T711, T731, T761 vented dryers
Specifications are subject to change without notice. See installation instructions for additional details.
The door hinges on ASKO dryers are
shipped left-hinged, but they are
reversible. See the Dryer Use and Care
Guide for more information.
When placing the dryer next to a wall or
cabinet, be sure to leave 1/2" (12 mm) of
space between the dryer and the wall or
cabinet.
See page 26 for stacked washer/dryer
dimensions.
See pages 2830 for cutout dimensions
for closet and under-cabinet installations.
NOTE: Power cord not supplied with unit.
Venting Requirements
WARNING! To reduce the risk of fire,
vented dryers must be exhausted
OUTDOORS or the equivalent.
Never cover the end of the dryer stub or
vent hose with anything to catch lint,
except for a UL-approved vent basket.
The exhaust hose should be run with as
few bends as possible to the point of
discharge. If necessary, it can be extended
to a maximum of 20 feet (610 cm) of 4 in
(10 cm) diameter ridged pipe. Make any
bends as gentle as possible. A maximum
of four 90° bends may be fitted in the
hose, otherwise the performance of the
dryer will be impeded. Subtract 4 feet of
exhaust hose for every 90° elbow.
If the exhaust hose is taken to a wall outlet,
a ventilation grill should be fitted to prevent
reverse flow of cold air. Fit the ventilation
grill to the outside or inside of the wall.
This appliance should not be exhausted
into a chimney, a wall, a ceiling, or a
concealed space of a building. Only a
metal ventilation grill should be used.
Unit Dimensions
US METRIC
HEIGHT 33-1/2"34-1/2" 850876 mm
WIDTH 23-7/16" 595 mm
DEPTH: T711, T731 24-7/16" * 621 mm
T761 23-7/16" 595 mm
DEPTH W/DOOR OPEN 46-1/16" 1170 mm
WEIGHT 86 lb 39 kg
Technical Data
Supply voltage Single-phase
230 V, 60 Hz
Heating element 2500 W (3000 W for T711)
Internal Fuse 15 A (Except T711)
NOTE: When on a separate outlet, use
220 V, 20 Amp single-phase circuit. When
an ASKO washer is connected, use 220 V,
30 Amp single-phase circuit.
Subtract 4 feet
(122 cm) for
every 90° elbow.
Installation
Examples