Specifications
30
ASKO’s front panel controls make it possible to
install the washers and dryers under a cabinet or
in a closet. Make sure there is a 1/2" (12 mm)
minimum clearance between units and between
units and cabinet or wall.
Every ASKO washer is delivered ready-fitted with
a plug and is intended for connection to an ASKO
dryer, which is equipped with a matching receptacle.
When an ASKO wash er is connected to the dryer,
use 220 V, 30 Amp sin gle-phase circuit. When the
dryer is on a separate outlet, use 220 V, 20 Amp
single-phase circuit. If the washer is used separately
or with another dryer, it must be on a separate
220 V, 20 Amp single-phase circuit.
NOTE: To avoid crimp ing the electrical and wa ter
con nec tions, do not in stall the hook ups be tween
the area of 26" to 35" from the floor.
Washer and Vented Dryer
T712 and T731 dryers can be vented from the rear
or the left or right side. The cabinet cutout illustrated
at right gives the dimensions for a rear and left
exhaust.
See page 24 for venting requirements.
WARNING! To reduce the risk of fire, vented dryers
must be exhausted OUTDOORS or the equivalent.
Never cover the end of the dryer stub or vent hose
with anything to catch lint, except for a UL-approved
vent bucket.
Washer and Condenser Dryer
ASKO condenser dryers must be installed to
continuously drain through a hose attached to the
rear of the machine. To ensure proper drainage,
the drain must not be higher than 40" above
the bottom of the dryer. See page 25 for
condensation drain requirements.
ASKO’s front panel controls make it possible to install the washers and dryers under a
cabinet or in a closet. Make sure there is a 1/2" (12 mm) minimum clearance between
units and between units and cabinet or wall.
Every ASKO washer is delivered ready-fitted with a plug and is intended for connection to
an ASKO dryer, which is equipped with a matching receptacle. When an ASKO wash er is
connected to the dryer, use 220 V, 30 Amp sin gle-phase circuit. When the dryer is on a
separate outlet, use 220 V, 20 Amp single-phase circuit. If the washer is used separately
or with another dryer, it must be on a separate 220 V, 20 Amp single-phase circuit.
Planning & Design: Laundry
SIDE-BY-SIDE UNDER-COUNTER INSTALLATIONS
Specifications are subject to change without notice. See installation instructions for additional details.
Cutout Dimensions
US METRIC
HEIGHT 34"–35-1/2" 864–902 mm
WIDTH 48-1/2"minimum 1232 mm
DEPTH 25" 635 mm
NOTE: For these installations, a custom
countertop may be required.
Vented Dryer Opening
Condenser Dryer Opening