Specifications

24
Specifications are subject to change without notice. See installation instructions for additional details.
Planning & Design: Dryers
T712C, T741 condenser dryers (ventless)
The door hinges on ASKO dryers are shipped left-hinged, but they are reversible.
See the Dryer Use and Care Guide for more information.
When placing the dryer next to a wall or cabinet, be sure to leave 1/2" (12 mm) of
space between the dryer and the wall or cabinet.
See page 27 for stacked washer/dryer dimensions.
See pages 28–30 for cutout dimensions for closet and under-cabinet installations.
Condensation Drain Requirements
You must install the dryer so the condensed water will continuously
flow into a drain or sink. To do this, follow the instructions below:
1. Disconnect the short hose (1) from the blue connection.
(It’s okay to let the hose hang down.)
2. Connect the rubber hose supplied with the dryer to the blue nipple (2).
3. Run the hose to a drain or sink, as illustrated.
NOTE: Power cord not supplied with unit.
NOTE: The drain hose must not be more
than 40" above the floor or the bottom of
the unit.
46-1/4"
1175 mm
24-7/8"
632 mm
Unit Dimensions
US METRIC
HEIGHT 33-1/2"–34-1/2" 850–876 mm
WIDTH 23-7/16" 595 mm
DEPTH: T712C 24-7/8" * 632 mm
T741 24-7/8" * 632 mm
DEPTH W/DOOR OPEN 46-1/4" 1175 mm
WEIGHT 103 lbs 47 kg
Technical Data
Supply voltage Single-phase
220 V, 60 Hz
Heating element 2500 W
NOTE: When on a separate outlet, use
220 V, 20 Amp single-phase circuit. When
an ASKO wash er is connected, use 220 V,
30 Amp sin gle-phase circuit.
1
3
3
40"
(1016 mm)
maximum
height
2
Back of dryer
*Includes 1" for control knob.