Operating instructions

Page 11
ENGLISH
ENGLISH
1. Connect the exhaust hose to a ventilation exhaust
fitting or to a discharge through the wall.
2. Secure the hose joint to the outlet stub on the
machine.
3. Run the hose with as few bends as possible to the
point of discharge. If necessary, it can be extended
to a maximum of 22 feet (660 cm) of 4” (10 cm)
diameter ridged pipe.
Make any bends as gentle as possible. A maximum of
four 90° bends may be fitted in the hose. The more
bends and the longer the hose, the less air will circulate
through the machine, which will impede drying
performance. Subtract 4 feet (120 cm) for every 90°
elbow.
CONNECTING CONNECTING TTO O A A VENTILAVENTILATION DUCT (T700/T760)TION DUCT (T700/T760)
WARNING!
This appliance should not be exhausted into a
chimney, a wall, a ceiling, or a concealed space of a
building. Only a metal ventilation grill should be used.
Subtract 4 feet
(120 cm) for
every 90° elbow.
Ventilation grill
FREESTFREESTANDING INSTANDING INSTALLAALLATIONTION
The dryer can be placed next to the washing machine.
It is essential that the machine is leveled and the
locknuts are tight to eliminate vibration.
There should be at least 1/2” (12.5 mm) of space
between the washer and dryer.
MODELS T700/T760
These models can be installed beneath a cabinet or
worktop with a minimum height of 34” (864 mm). There
must be a gap of about 1/4” (.64 mm) all around the
machine, including between the rear edge of the
machine top panel and the back wall. The opening width
must be at least 24” (600 mm).
Space must also be available for the exhaust hose on
the left, right or rear of the machine. See the diagram for
hole sizes and positions. Note that the hole
measurements are to the center of the hole.
BBUILUILTT-IN INST-IN INSTALLAALLATIONTION
NOTE: The height adjustment for the dryer is
33-1/2” to 34-1/2” (850 mm to 876 mm).
Do not raise it higher than 34-1/2”.
NOTE:
All hole measurements are
to the center of the holes.
NOTE:
MODELS T720/T780
The condensing models work best when they have
good air circulation. Therefore, we don’t recommend
that they be installed beneath a cabinet. If it is necessary,
however, be sure to leave a gap of at least 1/2” on all
sides.
Installation Examples
If more than 22 feet of hose is needed, the diameter
must be increased to 6” or 8” (152 mm or 203 mm).
Vent spacer
If the hose is taken to a wall outlet, a ventilation grill
should be fitted to prevent reverse flow of cold air. Fit the
ventilation grill to the outside or inside of the wall.
Make sure nothing is
blocking the ventilation grill.
If there is only one vent duct from the room, a vent spacer
must be fitted.
NOTE: When installing in warm climates (77°F and
above) with high humidity levels, do not
route the air exhaust hose upwards.