Specifications

ASKO´s front controls make it possible to install the
washers and dryers under a cabinet or in a closet.
Make sure there is a ¼˝ (6 mm) minimum clearance
between units and between units and cabinet or wall.
Every ASKO family-size washer is delivered
ready-fitted with a plug and is intended for connection
to an ASKO family-size dryer, which is equipped with
a matching receptacle. When an ASKO wash er is

circuit. When the dryer is on a separate outlet, use

family-size washer is used separately or with another

single-phase circuit.
NOTE: To avoid crimp ing the electrical and wa ter
con nec tions, do not in stall the hook ups be tween the area
of 26˝ (660 mm) to 35˝ (889 mm) from the floor.
Washer and Vented Dryer
T794FI, T784 and T754 family-size dryers can be
vented from the rear, left or right side. The cabinet
cutout illustrated at right gives the dimensions for a
rear and left exhaust. See page 33 for venting requirements.
WARNING ! To reduce the risk of fire, vented dryers must be
exhausted OUTDOORS or the equivalent.
Never cover the end of the dryer stub or vent hose with
anything to catch lint, except for a UL-approved vent bucket.
Washer and Condenser Dryer
ASKO condenser dryers must be installed to
continuously drain through a hose attached to the
rear of the machine. To ensure proper drainage, the
drain must not be higher than 40˝ (1016 mm) above
the bottom of the dryer. See page 37 for condensation
drain requirements.
NOTE: Condenser dryers require adequate
ventilation for proper operation.
NOTE: A louvered door is recommended for closet
installations using T754C condenser dryer.
ASKO´s front controls make it possible to install the washers and dryers
under a cabinet or in a closet. Make sure there is a ¼˝ (6 mm) minimum
clearance between units and between units and cabinet or wall.
Every ASKO family-size washer is delivered ready-fitted with a plug and is
intended for connection to an ASKO family-size dryer, which is equipped with
a matching receptacle. When an ASKO family-size wash er is connected to


single-phase circuit. If the ASKO family-size washer is used separately or with

PLANNING & DESIGN: 

Specifications are subject to change without notice.
See installation instructions for additional details.
Cutout Dimensions
 
 34˝ – 35˝ 864 – 889 mm
w
*
40˝ – 4 1016 – 1041 mm
 48˝ 1220 mm
 2 635 mm
*
Height with 6˝ (152 mm) HiddenHelper
installed
NOTE: For these installations, a custom countertop
may be required.
Family-size Washer / Dryer Opening (W6424)
25˝
(635 mm)
15 ¾˝ minimum
(400 mm)
4
3
/
8
˝
(111 mm)
4 ¾˝
(121 mm)
48˝
(1220 mm)
5 ½˝
(140 mm)
5 ½˝
(140 mm)
34˝ – 35˝
(864 mm – 889 mm)
40˝ to 41˝
(1016 mm – 1041 mm
with 6˝ (152 mm) HiddenHelper
)
NOTE:
Exhaust holes not required
for condenser dryers.
Cold Water
Drain
220V 30 Amp
Outlet
19 ½˝
(495 mm)
4 ¾˝
(121 mm)
5 ½˝
(140 mm)
5 ½˝
(140 mm)
34˝ – 35˝
(864 mm – 889 mm)
15 ¾˝ minimum
(400 mm)
48˝
(1220 mm)
Cold Water
Drain
220V 30 Amp
Outlet
25˝
(635 mm)
40˝ to 41˝
(1016 mm – 1041 mm
with 6˝ (152 mm) HiddenHelper
)
NOTE:
Exhaust holes
not required for
condenser dryers.
Family-size Washer / Dryer Opening (W6984FI, W6884 ECO)
*
Use when outer doors are reversed.
When HiddenHelper
is specified, see pages 47-48.
NOTE: A separation strip can be used vertically in the center of
opening to separate washer and dryer to provide a cosmetic reveal
cover. Additional width with cut out dimension should be added to
accommodate.
If possible, provide a rear access panel to enable access to water,
electrical & drain outlets in back.
40