Specifications

Specifications are subject to change without notice.
See installation instructions for additional details.
PLANNING & DESIGN: 

ASKO´s front controls make it possible to install the washers and
dryers under a cabinet or in a closet. Make sure there is a ¼˝
(6 mm) minimum clearance between units and cabinet or wall.
To ensure proper ventilation, we recommend louvered doors,
particularly for condenser dryers.
Every ASKO family-size washer is delivered ready-fitted with a
plug and is intended for connection to an ASKO family-size dryer
which is equipped with a matching receptacle. When an ASKO
family-size washer is connected to the ASKO family-size dryer,


single-phase circuit. If the ASKO family-size washer is used
separately or with another dryer, it must be on a separate

Vented Dryer Opening
T794FI, T784 and T754 family-size dryers can be vented
from the rear, left or right side. The cabinet cutout
illustrated below gives the dimensions for a rear exhaust.
See page 33 for venting requirements.
Condenser Dryer Opening
ASKO condenser dryers must be installed to continuously
drain through a hose attached to the rear of the machine.
To ensure proper drainage, the drain must not be higher
than 40˝ (1016 mm) above the bottom of the dryer.
See page 34 for condensation drain requirements.
NOTE: To avoid crimping the electrical and water
con nec tions, do not install the hookups between the area of
26˝ (660 mm) to 35˝ (889 mm) from the floor (as indicated
by shaded area in illustrations above).
For stacked installations, we recommend a 6' (1829 mm) cord.
Never cover the end of the dryer stub or vent hose with
anything to catch lint, except for a UL-approved vent bucket.
When HiddenHelper
is specified, see pages 46-47. The following
6˝ (152 mm) height HiddenHelpers models are available - HI115,
HDB115 , H B115 .
WARNING ! To reduce the risk of fire, vented dryers must be
exhausted OUTDOORS or the equivalent.
NOTE: A louvered door is recommended for closet
installations using an ASKO condenser dryer.
72
5
/
8
˝ – 73
3
/
8
˝
(1845 mm – 1870 mm)
with
6
˝
(152 mm)
HiddenHelper
)
72
5
/
8
˝ – 73
3
/
8
˝
(1845 mm – 1870 mm)
with
6
˝
(152 mm)
HiddenHelper
)
67 ½˝ – 69 ½˝
(1715mm – 1765 mm)
67 ½˝ – 69 ½˝
(1715 mm – 1765 mm)
220V 30 Amp
Single Phase
Outlet
See note
220V 30 Amp
Single Phase
Outlet
See note
Cold Water
Drain
Cold Water
Drain
Height with 6
˝
(152 mm)
HiddenHelper
:
4
4
1
/
8
˝
– 4
5
1
/
8
˝
(1156mm – 1181 mm)
4
3
/
8
˝
(111 mm)
24˝ minimum
(610 mm)
24˝
(610 mm)
15 ¾˝ min
(400 mm)
15 ¾˝ min
(400 mm)
39˝ – 40˝
(991 mm –
1016 mm)
25˝
(635 mm)
25˝
(635 mm)
72
5
/
8
˝ – 73
3
/
8
˝
(1845 mm – 1870 mm)
with
6
˝
(152 mm)
HiddenHelper
)
72
5
/
8
˝ – 73
3
/
8
˝
(1845 mm – 1870 mm)
with
6
˝
(152 mm)
HiddenHelper
)
67 ½˝ – 69 ½˝
(1715mm – 1765 mm)
67 ½˝ – 69 ½˝
(1715 mm – 1765 mm)
220V 30 Amp
Single Phase
Outlet
See note
220V 30 Amp
Single Phase
Outlet
See note
Cold Water
Drain
Cold Water
Drain
Height with 6
˝
(152 mm)
HiddenHelper
:
4
4
1
/
8
˝
– 4
5
1
/
8
˝
(1156mm – 1181 mm)
4
3
/
8
˝
(111 mm)
24˝ minimum
(610 mm)
24˝
(610 mm)
15 ¾˝ min
(400 mm)
15 ¾˝ min
(400 mm)
39˝ – 40˝
(991 mm –
1016 mm)
25˝
(635 mm)
25˝
(635 mm)
Cutout Dimensions
 
 67 ½˝ – 69 ½˝ 1715 – 1765 mm
w
*
72
5
8
˝ – 73
5
8
˝ 1845 – 1870 mm
 24˝ 610 mm
 25˝ 635 mm
*
Height with 6˝ (152 mm) HiddenHelper
installed
Height does not
include the height
of any vent duct
materials.
Height does not
include the height
of any vent duct
materials.
38