Specifications

Page 25 of 68
Camera System
One pinhole and three dome security cameras have been installed within the parkade. The
cameras have been installed at the following locations:
1 pinhole camera at the visitor intercom panel
3 dome cameras in the parkade
Owners can view security camera information on channel 116 analog, or 399 digital. A DVR will
record all information on the security cameras. When the DVR is full (500 giga bites or
approximately 3 weeks of information), it will record over the most dated information.
Garbage and Recycling Pickup
As of the date this Manual was printed, your garbage/recycling contract had yet to be negotiated.
Please contact the Fitzsimmons Walk strata manager for more information (Alex Hoelk, Whistler
Resort Management: 604-932-2972 ext. 243).
Water Shutoffs
As soon as possible, please re-familiarize yourself with the location of the water shutoff valves in
your home. These were pointed out to you during your initial orientation. Shut offs are usually
located in the storage rooms of your suite (concealed behind the removable panels), below the
sinks, behind the toilet, and/or in the laundry closets. Should you notice a plumbing leak, turn the
water off at these shutoffs, and immediately contact your property manager or our Customer
Service Department. Refer to the “Emergency Procedures” tab for contact information.
Bathroom Exhaust Fan
As required by the British Columbia Building Code (BCBC), principal exhaust fans, such as those
in the main bathrooms, must be on for a minimum of 8 hours per day. This requirement can be
increased, but it will never be decreased. To comply with this requirement, both your main and
guest ensuite bathroom fans have been set to run between between 9 am and 5 pm daily.
Please be aware that tampering with the fan timer operation (and not meeting the minimum
requirements) will void your entire home warranty.
Dryer Booster Fan
A booster fan has been installed to work in concert with the dryer. This fan will engage when the
dryer is on to assist in moving condensation out of the building. If a disconnect switch is present,
it will be installed in the laundry closet beside/adjacent the dryer - please note this switch has
been set in the on position for optimum dryer performance.
Please be aware that tampering with the disconnect switch, by turning it to the off position,
will void your entire home warranty. This switch should be used for service reasons only.
Heating and Cooling
Your new home is built with a heating and cooling system. For more information, please refer to
the Home Components section of this Manual.
Thermostat for Heating and Cooling System
Your heating/cooling thermostat is a Carrier/Debonair P/N 33CS420-01. For more information,
please refer to the Home Components section of this Manual.