Output
Header Default Function Defaults
OP1 +
RELAY1
Door Lock Output 1 (+ve)
Reader 1
OP1 -
Door Lock Output 1 (-ve)
OP2+
RELAY2
Door Lock Output 2 (+ve)
Reader 2
OP2-
Door Lock Output 2 (-ve)
OP3+
RELAY3
Door Lock Output 3 (+ve)
Reader 3
OP3-
Door Lock Output 3 (-ve)
OP4+
RELAY4
Door Lock Output 4 (+ve)
Reader 4
OP4-
Door Lock Output 4 (-ve)
OP5+
RELAY5
Door Lock Output 5 (+ve)
Reader 5
OP5-
Door Lock Output 5 (-ve)
OP6+
RELAY6
Door Lock Output 6 (+ve)
Reader 6
OP6-
Door Lock Output 6 (-ve)
OP7+
RELAY7
Door Lock Output 7 (+ve)
Reader 7
OP7-
Door Lock Output 7 (-ve)
OP8+
RELAY8
Door Lock Output 8 (+ve)
Reader 8
OP8-
Door Lock Output 8 (-ve)
RELAY1 to RELAY8 are set by default to function as door lock output for Reader 1 and
Reader 8. All relay function as 12V voltage output normally open relay setting
6.2 Output Select for Relay
Relay can be set to different output configurations via jumper settings:
NO (Normally Open)
NC (Normally Close)
12V output in NO configuration
12V output in NC configuration
The 4-pin header is for 12VDC or dry-contact (voltage free) output setting. The 3-pin
header is for normally closed (NC)/ normally open (NO) output setting. The following
figure depicts the output setting for Relays. There are 4-pin header and 3-pin header by
the side of each relay for jumper selection.