Specifications Sheet
AMERICAN SPECIALTIES, INC.
441 Saw Mill River Road, NY 10701
(914) 476.9000 • (914) 476.0688
www.americanspecialties.com
MOUNTING
HOLES
FOUR (4)
PLACES
7
8
" DIA [Ø22]
ELECTRICAL
KNOCKOUT
FOUR (4)
PLACES
11-
7
32
"
[285]
3-
15
16
" [100]
9-
21
64
" [237] 2-
9
64
" [54] REF1-
7
32
" [31]
12-
11
16
" [322]
15-
3
32
" [383]
2-
53
64
"
[72]
5-
7
16
" [138] 1-
37
64
" [40] REF
9-
27
32
" [250]2-
5
8
" [67]
1-
17
32
"
[39]
7-
9
32
"
[185]
2-
13
32
"
[61]
REF
3-
15
16
"
[100]
29
32
"
[23]
11
16
" [18]
1-
13
64
" [31]
NOTE:
ALL DIMS
INCH [MM]
Patented No. D 543,661 S
THIS MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES IN DESIGN OR DIMENSIONS WITHOUT FORMAL NOTICE
SURFACE MOUNTED SENSOR HAND DRYER WITH CAST IRON COVER (PG 1/2)
MODEL №: 0195
ISSUED: 10/05
REVISED: 01/10
SPECIFICATION
Surface Mounted Hand Dryer shall operate automatically from IR sensor that shall activate dryer when hands are placed in
sensor zone. Motor and heating element shall have internal resetting automatic thermal protection. Cover shall be fabri-
cated of one-piece, heavy-duty cast iron 1/4" (6.4mm) thick, and shall have all exposed surfaces finished with acid, chip and
scratch resistant porcelain enamel. Fixed directional air vanes shall be heavy duty, rust proof and tamper resistant. Air in-
take slots shall not allow access to internal parts. Back plate shall be furnished with vibration isolating mounting bushings.
Circuitry shall have self-adjusting time-out and fail-safe off protection controlled by a microprocessor that shall detect and
reject false signals and shall automatically self calibrate to provide uniform sensitivity over its entire life span. Entire unite
shall be internally electrically grounded. Dryer unit shall have C US approval and be listed under the re-
examination services of Underwriters Laboratories, Inc. Unit shall be warranted against defects in materials or work-
manship for ten (10) years.
Surface Mounted Sensor Hand Dryer shall be Model № 0195 of American Specialties, Inc. 441 Saw Mill River Road
Yonkers, New York 10701-4913
INSTALLATION
Unit is surface mounted on wall with four (4) 1/4" screws, washers and bushings (supplied) through rubber grommets (supplied)
in a corrosion protected formed heavy steel back plate into suitable prepared mountings (by others) or other suitable mounting
hardware (by others) to suit wall conditions. For masonry walls use expansion bolts or anchors for 1/4" (6) screws. Electrical
service is supplied and connected (by others) prior to installing cover. Cover is secured to back plate with two (2) hex socket
security screws (supplied). For compliance with ADA Accessibility Guidelines, install unit so that bottom edge of dryer is
48" (1219) MAX AFF if clear floor access is provided. For general utility install unit so that bottom edge of dryer is 54" to
56" (1372 to 1422) AFF. For two or more dyers, dryers should be no closer than 24" (610) on center.
OPERATION
Dryer is activated by user placing hands under sensor. Dryer automatically shuts off after time-out when user removes
hands from sensor zone.