Specifications

Command/Response Formats 119
Commands
Table 6.56 contains the possible warnings the receiver may issue.
Table 6.56: Receiver Warning Messages
Warning Definition Action
Int. Battery Error :
SMBus
The SMBus
controller (for the
internal battery
communication) is
not working
Remove battery and reinsert it. If problem
persists, insert a different battery. If problem still
persists, contact customer support.
Int. Battery Error :
Access
Can’t access the
internal battery
Remove battery and reinsert it. If problem
persists, insert a different battery. If problem still
persists, contact customer support.
Battery Conditioning
Required
Internal battery
efficiency is down, It
requires a
conditioning cycle.
Perform battery reconditioning (depends on the
battery, but typically means full charge, full
discharge and full charge again)
Low Int. Battery : < 10
min
Internal battery
remaining life is < 10
min, the battery needs
to be changed
Replace battery with a charged one.
Low Ext. Battery : <
30 min
External battery
remaining life is < 30
mn, the battery needs
to be changed. This is
only available if the
user has entered the
parameters of the
external battery via
the $PASHS,POW.
Replace battery with a charged one.
†Memory Test Error :
RAM
RAM error Perform a receiver initialization. If problem
persists, contact customer support.
†Memory Test Error :
BBRAM
Battery backed Ram Perform a receiver initialization. If problem
persists, contact customer support.
†Memory Test Error :
ROM
ROM, i.e. Flash Perform a receiver initialization. If problem
persists, contact customer support.
†Memory Test Error :
BOOT
Boot section of the
flash
Perform a receiver initialization. If problem
persists, contact customer support.
No Data Card Detected There is no card in the
PCMCIA drive or it
cannot be detected ->
no recording
Insert or reinsert data card in slot.
Data Card Full No space left on the
PC card, therefore
data recording is
stopped
Replace current data card with a card containing
available memory.