Specifications
96 Z-Family Technical Reference Manual
alarm will only disappear if the user acknowledges it (press any key), not if enough
satellites are tracked again.
Example: Set minimum number of satellites to 5.
$PASHS,MST,5 <enter>
MSV: Minimum SVs for Data Recording
$PASHS,MSV,d
Sets the minimum number of satellites required for measurement data to be output
and/or recorded, where d is a number between 1 and 9. Default is 3.
Example: Set minimum satellites to 4
$PASHS,MSV,4 <enter>
OUT,MET: Start Meteorological Meters Process
$PASHS,OUT,c,MET
,s
Start/stop the processing of the meteorological meters. It first initializes the meters
and then regularly queries them at the interval requested, where c is the port the
meteorological meters is connected to and s is ON or OFF.
Example: Start meteorological meter on port B.
$PASHS,OUT,B,MET,ON <enter>
Table 6.25: MST Parameter Table
Parameter Description Range Default
d Min. number of satellites required
for a kinematic survey.
0 = disable alarm
0, 4 - 9 0
Table 6.26: OUT,MET Message Structure
Parameters Description Range
c Serial port connected to meteorological meters. A - D
s enable /disable meteorological meters processing ON / OFF