Specifications
Command/Response Formats 95
Commands
Example: set *9900XY to the MET CMD field.
$PASHS,MET,CMD,C,9900XY <enter>
MET,INIT: Meteorological Meters Initialization
$PASHS,MET,INIT,
c,s
Set meteorological meters initialization string.
Example: set *9900ID to the INIT STRING_MET field.
$PASHS,MET,INIT,A,9900ID <enter>
MET,INTVL : Meteorological Meters Interval
$PASHS,MET,INTVL,
c,d
Set the interval for the query of the meteorological meters.
Example: set 10 to the MET SAMPLE field
$PASHS,MET,INTVL,D,10 <enter>
MST: Minimum SVs for Kinematic Survey
$PASHS,MST,d
Sets the minimum number of satellites required for kinematic survey, where d is that
number. If the number of satellites locked is below that minimum, an audible alarm
will go off (for a Z-surveyor or Z-FX, a message will be displayed on the LED). The
Table 6.23: MET,INIT Message Structure
Parameter Description Range
c Serial port connected to meteorological meters A - D
s initialization string of meteorological meters excluding the
s ta r t i n g ’* ’ si gn
limited to 20
alphanumeric
characters
Table 6.24: MET,INTVL Message Structure
Parameter Description Range
c Serial port connected to meteorological meters A - D
d sample interval for meteorological meters 5-9999 sec (default
= 5)