Instruction manual

Page 78 Z-12 Real-Time Sensor Operation and Reference Manual
Enter Site ID
$PASHS,SIT,X
This command sets the site name. The comand structure is
$PASHS,SIT,X
where x is a user-defined string of four characters.
Example: Set site name to 0001
$PASHS,SIT,0001
Set Communication Baud Rate
$PASHS,SPD
This command sets the baud rate of sensor serial port x. The command structure is
$PASHS,SPD,x,s
where x is A, B, or C, and s is a code number between 0 and 7 specifying the baud
rate as shown in Table 4.24. Default is 9600 baud..
3J16
Firmware version, 4 characters
C05
C = coprocessor, 05 = sensor option
1C63 Channel version, 4 characters
DP Options:
D = differential, base or remote
U = differential, rover only
P = photogrammetry
12 Code option:
1 = P code L1
2 = P code L2
M Remote monitor
Q 1/4-second (quick) update rate
L Low-power (sleep) mode
J Real-time Z option
Table 4.24: Communication Baud Rate
Code Baud Rate Code Baud Rate
0 300 5 9600
1 600 6 19200
Table 4.23: Configuration and Options (continued)
Field Description