Product Manual

Table Of Contents
343
Query Command Library
Parameters
Comments
With no internal battery in, fields f4, d5 and d7 are all empty.
With no external power source applied, field f6 is empty.
Example
$PASHQ,PWR
$PASHR,PWR,6.8,9.1,2,,,11.6,,44*0D
Relevant Set
Command
$PASHS,PWR,PAR
RAW: Raw Data Logging Settings
Function This command is used to query the raw data recording
parameters.
Command Format Syntax
$PASHQ,RAW[*cc]
Response Format Syntax
(Through an example):
PER:020.00 ELM:10
RAW: MPC DPC PBN SNV SNG SNW SAL SAG SAW ION SBD BAUD
Parameter Description Range
f1
Battery voltage threshold, in volts, triggering a low-bat-
tery alarm
6.7-8.4
f2
External power voltage threshold, in volts, triggering a
low-power alarm
9.0-28
d3
Power source:
0: Internal battery
1: External battery
2: External DC source
0-2
f4 Battery DC output voltage, in volts 0.0-12.0
d5 Percentage of remaining battery energy 0-100
f6 DC input voltage from external power, in volts 0.0-30.0
d7
Battery charging status:
0: Charging
•1: Discharging
2: Fully charged
0-2
d8 Internal temperature, in °Celsius
*cc Checksum *00-*FF