Query Command Library
ATM: ATOM Data Parameters
Function This command allows you to read the current settings of the
ATOM data-related parameters.
Command Format Syntax
$PASHQ,ATM[*cc]
Response format Syntax
(Through an example)
$PASHQ,ATM
PER:001.00 ELM:5
DRI:001.00 SIT:2007 REC:N MEM:M
ANH:02.132 ANT:VERT ANR:ON
ATOM: MES PVT ATR NAV DAT EVT BAUD
PRTA: OFF OFF OFF OFF OFF OFF 7
PRTC: OFF OFF OFF OFF OFF OFF 1
PRTE: OFF OFF OFF OFF OFF OFF 1
MEMM: OFF OFF OFF OFF OFF OFF 1
MEMU: OFF OFF OFF OFF OFF OFF 0
Parameters
Parameter Description Range
PER ATOM output rate 0.00-999.0 s
ELM
Elevation mask used in data recording &
data output
0-90
DRI Recording rate 0.00-999.0 s
SIT Site ID 4 characters
REC
Data recording:
Y: Data recording enabled
N: Data recording disabled
S: Data recording enabled but stopped
Y, N , S
MEM
Selected memory:
M: Internal memory
U: USB memory
M, U
ANH Antenna height 0.000-99.999
ANT Height measurement type (slant/vertical) SLANT, VERT
ANR Antenna reduction mode ON, OFF, ARP
PRTA ON, OFF
PRTC Label for Bluetooth ON, OFF
PRTE Label for Modem ON, OFF
MEMM
MEMU
Labels for memories ON, OFF