Product Manual

Table Of Contents
139
Miscellaneous
Base
*: Message type 1, 3, 9, 16, 18, 20, 22, 23, 24, 31, 32, 34
or 36.
**: Message type 1001, 1002,.. 1013, 1019, 1020, 1029
or 1033.
Position elevation mask 0-90°
Incoming differential data Automatic, Manual Automatic
Incoming differential port 1 A, C, D, E
Incoming differential port 2 A, C, D, E
Parameter Range Default
Parameter Range Default
Differential data type 1
NONE, ATM, RT2
(RTCM2.3), RT3
(RTCM3.x), CMR, CMR+,
DBN
RT3
Differential data port 1 A, C, E, M, U A
Differential data type 2
NONE, ATM, RT2
(RTCM2.3), RT3
(RTCM3.0), DBN (DBEN),
CMR, CMR+
NONE
Differential data port 2 A, C, E, M, U A
RTCM 2.3 type xxx rate* 0-300 s
Type 18: 1 s
Type 19: 1 s
Type 23: 31 s
Type 24: 13 s
Other: 0
RTCM 3.x type xxx rate** 0-300 s
Type 1004: 1 s
Type 1006: 13 s
Type 1012: 1 s
Type 1033: 13 s
ATOM scenario xxx *** 0-1800 s
Scenario No.: 4
Observations: 1 s
Attributes: 31 s
CMR station ID 0-31 1
RTCM2.3 station ID 0-1023 1
RTCM3.x station ID 0-4095 1
CMR type 0 rate 0, 0.5 s, 1-300 s 1 s
CMR type 1 rate 0-300 s 30 s
CMR type 2 rate 0-300 s 30 s
CMR type 3 rate 0, 0.5 s or 1-300 s 1 s
Base position (lat, lon,
height)
0°, 0°, 0 m
Elevation mask 0-90 degrees 5 degrees