Specifications

Operating Manual - ne24.24M Matrix Processor
18
store in a convenient place for future reference. If the password is forgotten, a limited password reset can be done by pressing
and holding the factory reset switch for two seconds during power up. Note: Holding the reset switch for a full 10 seconds dur-
ing power up will perform a full factory reset, changing all presets to the factory default.
9.5 Metering
Separate software tabs allow for input/output metering in dBu, as well as dynamics metering in dB.
10 REMOTE CONTROL
Ashly makes several remote control options which can be used
with the ne24.24M. The WR-1, WR-1.5, and WR-2 are passive wall-box
mounted remotes which can adjust volume or select presets. The WR-5
and neWR-5 are active programmable button controllers with user de-
ned button functions and an LED display, also wall-box installed. Each
requires a standard decora plate, purchased separately.
The RD-8 and FR-8/16 are programmable fader remotes, and do
not require an additional decora plate.
10.1 WR-1 Volume Control
The WR-1 is an assignable, dual potentiometer remote volume
control for the ne24.24M. Each volume control is connected to a ter-
minal block on the WR-1 circuit board, which in turn must be wired to
the ne24.24M back panel euroblock connector
labeled “0 - 5 Volt Remote Level Control”. Do
not connect the WR-1 remote level control ground
to any other external grounds. By connecting a
volume control to a specic pin (1-8), that pin
can be assigned in an input or output main control
surface "Remote" tool to control level. It is pos-
sible to simultaneously select the same input or
output channel to multiple remote level control
pins. Note, however, that the resulting attenua-
tion on that channel is cumulative, meaning that
channel’s gain is set by combining the value of
all remote level controls assigned to that channel.
In addition to using a WR-1 as the con-
trol device, the remote level control feature can
be used for relay activated muting of selected
channels, as in a re alarm application. Level
control is “attenuate onlymeaning that the maxi-
mum setting of the control potentiometer (fully
clockwise) results in 0 dB gain of the controlled
channel. A label template can be found on the
Ashly website for printing input or output channel
names under control of the WR-1 and sliding the
paper behind the mylar overlay windows.
The two +5V pins and two ground pins
on the WR-1 euroblock connector are tied together on the circuit board, so it is only necessary to run one +5V line and one
ground line to the WR-1 from the ne24.24M. These pins are provided for daisy-chaining multiple WR-1 controllers together.