5. REAR PANEL FEATURES
5.1 Input Connections
Balanced input signals are connected to the 24.24M using the included "Euro
Block" connector. A flat blade screwdriver is required to connect a stripped wire
lead to the loose connector, which is then inserted into the rear panel Euro Block
receptacle. It is important that both (+) and (-) inputs are properly terminated or
signal loss and noise may result. In other words, if an unbalanced input signal is
used, connect the signal to the (+) input, and connect the ground wire to both the
(-) and ground connection.
5.2 Output Connections
Like the inputs, output connections are made using the included "Euro Block" connector. All outputs are servo
balanced, and may be wired balanced or unbalanced. For unbalanced output connections, use (+) and ground and tie (-
) to ground.
5.3 Expansion Modules
The 24.24M base model is expandable by up to 16 additional inputs or outputs. Expansion modules of four inputs
or four outputs each can be installed. Input expansion modules use green Euroblock connectors, while output expansion
modules use black connectors. Removable metal plates cover unused expansion slots on the back panel.
5.4 Preset Recall
There are no user controls on the 24.24M, making it ideal for permanent installations where security is an issue.
There may be times, however, where real time variables require changes in system settings, such as EQ, gain, and delay
settings changing when a room size changes. For these types of changes, the 24.24M offers the ability to recall up to
eight different presets using contact closures. Contact closures are nothing more than external, user installed switches
that, when closed, recall a previously defined preset which at once applies changes to the settings of all inputs and
outputs. The switches can be anything from a rotary switch on a control room panel, to automatic door sensors scattered
throughout a conference center, to a microphone key switch, etc. Contact closures allow for flexibility while maintain-
ing a high degree of system security.
To use contact closure switching, up to eight presets (1-8) must first be defined according to the needs of the
installation. Switches are to be configured so that closing the switch contact triggers the preset recall event. It doesn't
matter if the switch is momentary or latching, the only thing that triggers the event is the transition from open to closed
for a given circuit. Closing a circuit will automatically override any previously recalled presets. Up to eight switches
Euroblock
Connector