Installation Guide

INSTALLATION (CONTINUED)
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
IMPORTANT: This appliance should only be installed by a qualified installer.
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1.
Installer l'appareil selon les codes ou règlements locaux, ou en l'absence de tels règlements, selon les codes
d'installation Code d'installation du gaz naturel et du propane, CSA B149.1.
IMPORTANT
· The appliance area must be kept clear and free from combustible materials, gasoline, and other
flammable vapors and liquids.
· Due to high temperatures, the appliance should be located out of traffic and away from furniture and
draperies.
· Children and adults should be alerted to the hazards of high surface temperature and should stay
away to avoid burns or clothing ignition.
· Young children should be carefully supervised when they are in the same room as the appliance.
· Clothing or other flammable material should not be placed on or near the appliance.
· Any safety screen or guard removed for servicing an appliance must be replaced prior to operating
the appliance.
Installation and repair should be done by a qualified service person. The appliance
should be inspected before use and at least annually by a qualified service person.
More frequent cleaning may be required due to excessive lint from carpeting, bedding
material, etc. It is imperative that control compartments, burners and circulating air
passageways of the appliance be kept clean.
WARNING: Failure to position the parts in accordance with these diagrams, or failure to use only
parts specifically approved with this appliance may result in property damage or personal injury.
AVERTISSEMENT: Risque de dommages ou de blessures si les pièces ne sont pas installées
conformément à ces schemas et ou si des pièces autres que celles spécifiquement aprouvées avec cet
appareil sont utilisées.
INSTALLING THE APPLIANCE
Separate the hanging bracket from the appliance by removing two screws on the top and two nuts at the
bottom.
INSTALLING THE HANGING BRACKET ON A NON-COMBUSTIBLE WALL (i.e.,
MASONRY BLOCK OR CONCRETE)
1. Draw the position of the hole for the air-vent intake pipe, taking into account the minimum clearances mentioned
in figure 4. See diameter of the hole “D” and height to the center “C” in table 1 and figure 5 for the different models.
Height “C” is the minimum recommended.
6