11.4 Minimum / Maximum Display
In Pressure Display Mode or Linear Display Mode the maximum
and minimum values are captured into nonvolatile memory (EEP-
ROM). The following steps describe how to display these values.
A. Maximum Value
In Measurement Mode (either pressure or linear indication
mode), press UP
$
button to display the maximum value. The
letter “H” will follow the reading indicating this is the maximum
value. Press the UP
$
button again to return to Measurement
Mode. Note: If the button is held for 3 seconds it will go into
zero adjustment mode.
088.2 k
Peak Hold Display
Pressure Display Mode
Pressure Range 100 psi
100
88.2
psi
Peak Hold Value
Pressure Data
Hold Reset
Time
Peak hold indication start
W
key is on more than
three seconds
X
key ON
0
Pressure (psi)
B. Minimum Value
In Measurement Mode (either pressure or linear indication
mode), press DOWN
#
button to display the minimum value.
The letter “Lwill follow the reading indicating this is the mini-
mum value. Press the DOWN
#
button again to return to
Measurement Mode.
Pressure Display Mode
Pressure Range 100 psi
Hold reset
Time
Peak hold indication start
W
key is on more than
three seconds
W
key ON
100
12.1
0
Pressure (psi)
Bottom hold value
Pressure
data
012.1 l
Bottom Hold Display
psi