Instruction Manual
G2, G3, GV & T2 PRESSURE
TRANSMITTER INSTRUCTION SHEET
WARNING! READ
BEFORE INSTALLATION
1. GENERAL:
A failure resulting in injury or damage may be
caused by excessive overpressure, excessive
vibration or pressure pulsation, excessive instru-
ment temperature, corrosion of the pressure con-
taining parts, or other misuse. Consult Ashcroft
Inc., Stratford, Connecticut, USA before installing
if there are any questions or concerns.
2. OVERPRESSURE:
Pressure spikes in excess of the rated overpressure
capability of the transducer may cause irreversible
electrical and/or mechanical damage to the pressure
measuring and containing elements.
Fluid hammer and surges can destroy any pressure
transducer and must always be avoided. A pressure
snubber should be installed to eliminate the dam-
aging hammer effects. Fluid hammer occurs when
a liquid flow is suddenly stopped, as with quick
closing solenoid valves. Surges occur when flow is
suddenly begun, as when a pump is turned on at full
power or a valve is quickly opened.
Liquid surges are particularly damaging to pressure
transducers if the pipe is originally empty. To avoid
damaging surges, fluid lines should remain full (if
possible), pumps should be brought up to power
slowly, and valves opened slowly. To avoid damage
from both fluid hammer and surges, a surge cham-
ber should be installed.
Symptoms of fluid hammer and surge’s damaging
effects:
• Pressure transducer exhibits an output at zero
pressure (large zero offset).
• Pressure transducer output remains constant re-
gardless of pressure
• In severe cases, there will be no output.
FREEZING:
Prohibit freezing of media in pressure port. Unit
should be drained (mount in vertical position with
electrical termination upward) to prevent possible
overpressure damage from frozen media.
m m
M12 ELECTRICAL TERMINATION
FOR T2 (EW), (EO), (E2), (E1)
Mates to optional Hirschmann connector
Part 933 172-100 or equal
Pin Voltage 4-20mA Mating
No. Output Output* Cable Color
1 V + V + Red
2 Output None White
3 Case Gnd. Case Gnd. Green
4 Common Common Black
IP65 Ingress rating
DIN 43650 FORM A (EN 175301-803-A)
ELECTRICAL TERMINATION
(DN), (DO), (D2), (D1)
Mates to optional Hirschmann connector
GDM 3009 or equal
Pin Voltage 4-20mA Mating
No. Output Output* Cable Color
1 V + V + Red
2 Common Common Black
3 Output None White
GND Case Gnd. Case Gnd. Green
IP65 Ingress rating
4-PIN BENDIX STYLE ELECTRICAL
TERMINATION (B4), (H1), (L1), (P2)
Mates to optional Amphenol Bendix connector PTO6A-8-
4-SR or equal
Pin Voltage 4-20mA Mating
No. Output Output* Cable Color
A V + V + Red
B Output None White
C Case Gnd. Case Gnd. Green
D Common Common Black
IP65 Ingress rating
SHIELDED CABLE, PVC JACKET, 24
AWG LEADS, TERMINATION (F2), (P1)
Wire Voltage 4-20mA
Color Output Output
Red V + V +
White Output None
Black Common Common
Green Case Gnd. Case Gnd.
Bare** Drain Wire Drain Wire
IP65 Ingress rating
© 2018 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA,
Tel: 203-378-8281, Fax 203-385-0402, www.ashcroft.com
All sales subject to standard terms and conditions of sale.
All rights reserved. G2, G3, GV, T2_transducer_IM_Rev1_07-18 (011-10129)
T2 ELECTRICAL TERMINATIONS AND WIRING
T2 ELECTRICAL TERMINATIONS AND WIRING
* Use either V- termination on G2 and GV with 4-20mA output
** Where shielded wiring is being used; Connect the drain wire to the guard
terminal on the read out device or measuring instrument if available. In all
other cases connect to the ground of the power supply negative terminal.
G2, G3. GV ELECTRICAL TERMINATIONS AND WIRING G2, G3. GV ELECTRICAL TERMINATIONS AND WIRING
16 7 8
SHIELDED CABLE, PVC JACKET,
24AWG LEADS
Wire Voltage 4-20mA
Color Output Output*
Red V + V +
Black Common V –
White Output V –
Bare** Shield Shield
Drain Wire Drain Wire
IP67 Ingress rating
FLYING LEADS 18AWG
Wire Voltage 4-20mA
Color Output Output*
Red V + V +
Black Common V – V –
White Output
IP67 Ingress rating
DEUTSCH DT SERIES DT04-3P
Pin Voltage 4-20mA Mating
No. Output Output* Cable Color
1 (B) Common V – Black
2 (C) Output V
– White
3 (A) V + V
+ Red
3 (A)
2 (C)
1 (B)
* Use either V- termination on G2 with
4-20mA output
DEUTSCH DTM SERIES DTM04-3P
Pin Voltage 4-20mA Mating
No. Output Output* Cable Color
1 V + V + Red
2 Common V
– Black
3 Output V
– White
3
2
1
* Use either V- termination on G2 with
4-20mA output
* Use either V- termination on G2 with 4-20mA output
.23
1.76
Wire
Length
.95
(45)
(6)
(24)
1.06
(27)
Pin Voltage 4-20mA Mating
No. Output Output* Cable Color
1 V + V + Red
2 Common V – Black
3 Output White
IP65 Ingress rating
DIN 43650 FORM C (EN 175301-803-C)
ELECTRICAL TERMINATION
(DC), (N1), (N2), (N3), (N9)
Mates to Hirschmann P/N: GSSNR 300,
Ashcroft P/N 300A126-01
Connection - PIN
1
2
3
V out
Vs
-
Vs
+
3-PIN DELPHI (PACKARD)
METRI-PACK 150 SERIES
Mates to Optional Metri-Pack connector 12065287
Pin Voltage 4-20mA Mating
No. Output Output* Cable Color
A Common V – Black
B V + V + Red
C Output V
– White
IP67 Ingress rating
* Use either V- termination on G2 with 4-20mA output