Submittal Sheet

BULLETIN SW10
Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
Tel: 203-378-8281 • Fax: 203-385-0408
email: info@ashcroft.com • www.ashcroft.com
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
© Ashcroft Inc. 2007 10/08
B-Series Switches – Pressure, Differential
Pressure, Temperature & Hydraulic
B-SERIES SWITCH OPTIONS
Appicable Switch Series
Differential Temp-
Pressure Pressure erature H
All
Code Description
(psi) (in. H
2
O) (psi) (in. H
2
O) Ranges Notes
XBP Wall Mounting Bracket in. H
2
O ••
XBX
1
2˝ Male NPT Bushing
XCH Chained Cover
XC8 CSA Approval
11
XCN ATEX Directive 94/9/EC EEx d IIC T6
XFM FM Approval – Single Element
17
FM Approval – Dual Element
17
XFP Fungus Proofing
XFS Factory Adjusted Setpoint
2
XG3 Belleville Actuator
16,17
XG5 UL Limit Control to 150˝ H
2
O•
1, 17
XG6 UL Limit Control to 600 psi
1, 17
XG7 Secondary Chamber with Vent
13
XG8 Steam Limit Control to 300 psi
7
XG9 Fire Safe Welded Actuator
7
XHS High Static Differential Pressure
15
High Pressure, 40 psi, (static) d/p only
XHX 160 psi (proof) d/p only
100 psi (proof) pressure only (˝ H
2
O)
XJK Left Conduit Connection
9
XJL
3
4˝ to
1
2˝ Reducing Bushing
XJM Metric Electrical Conduit Connection
M20 x 1.5
XK3 Terminal Block (700 Series only)
6
XLE 6 foot Leads on the Micro Switch
XNH Tagging Stainless Steel
XNN Paper Tag
XPK Pilot Light(s) Top Mounted
4
XPM
3
4˝ Sealed Conduit Connection
with 16˝ Lead Wires
XTA 316 Stainless Steel Pressure
Connection for in. H
2
O Range
XTM 2˝ Pipe Mounting Bracket •••
XUD 316 Stainless Steel Pressure Conn.
Pressure Connection:
X06
1
2 NPT Male,
1
4 NPT Female ••••
5
316 Stainless Steel (Combination)
X07
1
2 NPTF Press. Conn., 316 SS ••
10
X6B Cleaned for Oxygen Service
3
Diaphragm Seal
NOTES:
1 Buna N and Viton diaphragm.
2 Advise static or working pressure for differential pressure switches.
3 Buna N cannot be cleaned for oxygen service.
4 N/A on 700 Series.
5 Standard with 1000 and 3000 psi ranges. Bottom connection only
on DP in H
2
O ranges.
6 Terminal Blocks standard with 700 dual switches.
7 Stainless steel diaphragm only.
8 Pressure connection
1
4 NPTF.
9 Standard on 700 Series. N/A with DPDT element on 400 Series.
10 N/A with Monel diaphragm.
11 Standard on 400 Series.
12 N/A on 3000 psi range. Available with Teflon diaphragm only.
13 SS diaphragm required. Teflon diaphragm is the backup.
NEMA 7 only.
14 Available in ranges vacuum to 600 psi. Not available with stainless
steel or Monel diaphragm.
15 Buna N and Viton diaphragm – 15#D & 30#D only.
16 24, 32, 64 or 68 element only.
17 N/A on all combinations.
18 700 Series only.