Operating instructions
TD 92579GB
2009-04-15/ Ver. B
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 3.0.x)
85
Figure 49 .
Figure 33. Connected RFPs to the IPBL
2 Click the applicable port to open the RFP details pop-up window.
Figure 50 .
Figure 34. RFP Details
Figure 51 .
Note: If BER differs from 0, inspect the RFP cable.
Port The port used in the IPBL.
Status Current status of the IPBS connected to the IPBL.
Description A short description to help identify the IPBS.
RFPI Identity number.
SW Version The current software version.
Hardware The hardware version.
Boot RFP boot version.
Connected Time The elapsed time since the RFP connected to the IPBL.
Cable Delay The delay caused by the cable.
Tx Error The number of transmitting errors.
Rx Error The number of receiving errors.
BER SC0 Bit Error Rate SC0. Normal value: 0.
SER SC1 Bit Error Rate SC1. Normal value: 0.