Operating instructions
TD 92579GB
2009-04-15/ Ver. B
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 3.0.x)
80
Example:
The following example is a description of a not allowed air sync ring:
- Base Station A configured to listen to B
- Base Station B configured to listen to C
- Base Station C configured to listen to A
8.6 VoIP
This section only applies if the SIP protocol is used in the system.
8.6.1 Add instance id to the user registration with the IP-PBX
This might simplify administration with some IP-PBXs.
1 Select VoIP > SIP.
2 To enable, select the "Add instance id to the user registration with the IP-PBX"
check box.
3 Click "OK".
8.6.2 Session Timer (initial value)
If set, a keep-alive mechanism will be used to detect if a call is still valid as defined by rfc
4028. This is normally handled by the IP-PBX and then not necessary to be defined here.
1 Select VoIP > SIP.
2 To enable, enter a time (sec.) in the "(Session Timer initial value)" field.
3 Click "OK".
8.7 UNITE
8.7.1 Configure Messaging
If an IMS/WSM is to be used in the IP-DECT system, enter the IP address following the
steps below.
1 Select UNITE > SMS.
Note: To access the SMS tab, the Master mode has to be activated, see 8.5.12
Select Mode on page 70.
2 Enter the address to the IMS/WSM in the IP Address text field.
3 Click "OK".
If the communication between the Master and the IMS/WSM should be encrypted, do as
follows:
1 Select the Encryption check box.
Note: When selecting or clearing the Encryption check box, it may take up to a
couple of minutes until the IMS/WSM is fully operational.
Note: The IMS/WSM support for encryption is depending on the IMS/WSM
software version.