Operating instructions
TD 92579GB
2009-04-15/ Ver. B
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 3.0.x)
73
2 Enter the registration name and number to the PBX in the Registration Name /
Number text fields.
3 Select the "Deactivate Master if no connection" check box to make the Master
deactivate itself if the anonymous registration to the PBX fails. As a result the local
host Radio will fail to register to the Master, and Portable Devices, depending on
their type, can move to another Radio that is operable.
Note: It is not recommended to use this option for a Master without a Standby Master.
4 Click "OK".
Note: A simpler and reliable way to handle this case is to deactivate the local host Radio
on the Master.
8.5.17 Select Mobility Master Mode
In a system with two or more Masters (Multiple Master system), a Mobility Master must be
configured. For more information on Multiple Master Systems, see the document System
Planning, Ascom IP-DECT System, TD 92422GB.
1 Select DECT > Mobilty Master.
2 Select in the Mode drop-down list:
• "Active", if this IPBS/IPBL is the Mobility Master.
• "Standby", if this IPBS/IPBL is the Standby Mobility Master.
3 If you have selected the "Standby" mode: Enter the primary Mobility Master IP
address in its text field.
4 Write a login name in the Name text field.
5 Enter a password in the Password text field.
6 Click "OK".
7 Reset in order to make the changes take effect, see 8.16 Reset on page 113.
8.5.18 Connect Mobilty Master to other Mobility Master(s)
1 Select DECT > Mobilty Master.
2 Write a name in the Name text field.
3 Enter a password in the Password text field.
4 Enter the address to the other Mobility Master in the IP Address text field.
5 Enter the address to the Standby Mobility Master for the other Mobility Master in
the Alt. IP Address text field.
6 Click "OK".
7 Repeat the above steps to connect to additional Mobility Masters.
8 Reset in order to make the changes take effect, see 8.16 Reset on page 113.
8.5.19 Connect Master to a Mobility Master
In a system with several Masters, all Masters must be connected to the Mobility Master.
1 Select DECT > Master.
2 Write the name for the Mobility Master in the Name text field.
3 Enter the password for the Mobility Master in the Password text field.